User Tools

Site Tools


projects:maps:digitizer

Übersicht

Nomenkl.
hier immer frisch

Digitzer modules

Purpose of the digitzer modules shown in the picture below is to convert the analog current signals received from the BCTs into a proportional pulse frequency. By counting the derived digital pulses an integral value is calculated in between a measurement gate called “Rahmenpuls”. A precisly timed measurement is of only possible if the gate pulses are applied synchroneously to the beam signal, which is assured by application of an internal delay of each gate signal with respect to the beam's time of flight and the location of the individual BCT, respectively.

The primordial purpose of the MAPS-system was to display the correct timing of the gate pulses, enabling the adjustment of the cgate and beam pulse's congruence.

EPLD3 (FG 428.005.010).pdf geordneter
3.1996-N.Schneider
4.1999-Langer
schaltung
EPLD3 (FG 428.006).pdf besser beschriftet
FG 428 006
15.11.1996

Y-Adapter

← In gelb: Der Signalpfad der individuellen Klemmpulse an die Trafos ab CPLD (Signal #41 - Pin 36)

← Stecker/Verbinder vom und zum Board

Das grün hervorgehobene Signal ist das eingehende Rahmenpulssignal als eines von acht möglichen im UNILAC-Bereich. Es wird dem CPLD zugeführt. Dort können Laufzeitverzögerungen programmiert werden, sollte das notwendig sein, wenn Entfernungen eine individuelle Anpassung pro Trafostandort bedingen. Der verzögererte Rahmenpuls wird als Signal “#2” aus dem CPLD ausgeben und über zwei Buffer dann stark grün auch aus dem Digitizer heraus an VG1.Pin14 in den Verdrahtungsrückraum des Trafo-Crates geführt. Auf diesem Weg wird es auch auf zwei zweipolige LEMO-Buchsen der Größe “0S” auf der Craterückseite geführt und könnte so benutzt werden. Allerdings scheint keine dieser Ausgabebuchsen benutzt zu sein: die Ports auf dem Foto sind unbenutzt….
Somit reichen offensichtlich auch für das Timing der Verlustüberwachung die eingehenden gröberen Zeitscheiben/Zeitzonen aus: wenn z.B. ein Standardstrahlpuls deutlich größer 100 µs lang ist, dann macht eine individuelle Verschiebung um wenige µs wohl keinen Unterschied, da in der Verlustüberwachung kein Stromwert aus I = nQ/Δt bestimmt wird, sondern nur eine Differenz in reinen Pulszahlen. Denn die Digitizer der Pulsüberwachung summieren nur Pulse immer zweier aufeinander folgenden Trafos der Art, dass die Pulse von denen des Ersten abgezogen werden. Für diese Differenz ist die Schärfe der Zeitscheibe weniger relevant.
Genauer dürfen die verzögerten Rahmenpulsen gar nicht benutzt werden, denn wenn beide individuell verschieden für ihren Trafo sind, dann ist keines allein richtig für Modul wo beide gemeinsam aber invers gezählt werden!

Trafo-Crate mit Digitizern
Frontseite Rückseite Bemerkung
MIL-Bus-Karte Digitizers Rückfront Interlockausgang 2pol. LEMO 0S für: ? Übersteuerung ?
Analogausgang BNC (von 8x Digitizer vorne an MAPS-Interface)
verzög. Rahmenpuls 8×2 Ausgang LEMO 001) (Zum alten MAPS-PC)

Here 2 digitizer channels are shown. The cable with D-Sub connector passes the signals from the front end of the BCT electronics. A BNC jack for the analogue signal is provided at the front panel, as well as a Lemo jack for the delayed gate pulse. Both signals are also available on similar connectors on the crate's back panel. These are connected with the MAPS adapter.

"System for Nomenclatures of Accel. Device at FAIR & GSI

Following document reflects the result of the group over spanning Neomenclature commitiy: ACC-Nomenklatur:

V V accelerator systems or
comprehensive systems
[GE, GH, GK, GS, GT, GU, ER,
FM, FP, 1S, 3S, TL, TV, … ] or
[A, D, K, O, P, X]
V V beamline section, period or vacuum section [0..9,A..Z] letter or number
V V physical or technical group (group + device type) [A..Z] letter only
V device sequence indicator or function specifier [A..Z] letter or number
V device function specifier [A..Z] letter or number
V function specifier [A..Z letter only]
/ seperator [ / ]
V responsibility id [0..9,A..Z]
naming for cables [0..9,A..Z] letter or number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
G T K 7 D S 2 H R / i.e.: Slit,horizontal,right
T 1 S 1 D G 8 G P / i.e.: Tranfer to SIS100-MWPC pressure drive
K K 1 i.e.: “LSB1”
K K C A i.e.: “Cave A control room”
K K E 4 D R 1 2 R i.e.: “Eltr. room” row 4 diagnose rack 12
(combination _ _ _ _ D R _ _ R → Rack)
1 S 6 2 D T 2 H R / Trafo in Sektor 6 Zelle 2 (bis F)

At present state latest ACC-nomenclarture (Jan.2012) ends with defining rack rows in electronic rooms: first four positions in nomenclature (komprehensive system + section positions) are of form KK_x, where letters in thirth position are reserved until “P”. There might b

1)
Laufzeitkorrektur Kabel
projects/maps/digitizer.txt · Last modified: 2024/04/19 09:55 by carsten