ID | Beam Line | Chamber | Nomenklature | Chamber Type | Linear Actuator Type | Detector Sensitive Area | Detector Type | Envelops [mm/mm] | Forseen Location | Tunel Type | Tunnel width [m] | Transport way width [m] | Remarks: |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | T1S1 | Mo1 | T1S1DK1 | ???? | 30/50 | left, up | B013L | 6,4 | 2,3 | geplante FAIR-Beschaffung: at this position new design is required. SEM-Grid, MWPC, PDC and Foil Stripper shall be installed, Entry and Exit Flanges 2xCF150, Flange for vacuum pump: 1xCF150, Flange for vacuum measurements: 2xCF40 Flange for detector: 3xCF200, Flange for Foil Stripper: tbd | |||
MWPC | T1S1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | T1S1DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
PDC | T1S1DI1 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | ||||||||
2 | T1S1 | Mo2 | T1S1DK2 | BPM+FT-DK 2070+IPM | 30/30 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T1S1DX1 | / | / | ||||||||||
SCR | T1S1DF2 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | ||||||||
IPM | T1S1DF2G | / | Detector: up and right, PL: left | ||||||||||
3 | T1S1 | Mo3 | T1S1DK3 | FT-DK 2070 | 60/50 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
SCR | T1S1DF3 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | ||||||||
4 | T1S1 | Mo4 | T1S1DK4 | FT-DK 2030 | 60/30 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
MWPC | T1S1DG4G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | T1S1DG4 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
5 | T1S1 | Mo5 | T1S1DK5 | FT-DK 2010 | 50/30 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
SCR | T1S1DF5 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | ||||||||
6 | T1S1 | Mo6 | T1S1DK6 | BPM+FT-DK 2010 | 50/40 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T1S1DX2 | / | / | ||||||||||
SCR | T1S1DF6 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | ||||||||
7 | T1S1 | Mo7 | T1S1DK7 | FT-DK 2030 | 50/50 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
MWPC | T1S1DG7G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | T1S1DG7 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
8 | T1S1 | Mo8 | T1S1DK8 | BPM+FT-DK 2050 | 80/40 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T1S1DX3 | / | / | ||||||||||
MWPC | T1S1DG8G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | T1S1DG8 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
PDC | T1S1DI8 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | ||||||||
9 | T1S2 | Mo1 | T1S2DK1 | BPM+FT-DK 2030 | 50/60 | left, up | A10 | 7,8 | left: 2,3 | India Inkind | |||
BPM | T1S2DX1 | / | / | right: 2,2 | |||||||||
MWPC | T1S2DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | T1S2DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
10 | T1S2 | Mo2 | T1S2DK2 | BPM+FT-DK 2050+IPM | 50/30 | left, up | A10 | 7,8 | left: 2,3 | India Inkind | |||
BPM | T1S2DX2 | / | / | right: 2,2 | |||||||||
MWPC | T1S2DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | T1S2DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
PDC | T1S2DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | ||||||||
IPM | T1S2DF2G | / | Detector: up and right PL: left | ||||||||||
11 | T1S3 | Mo1 | T1S3DK1 | BPM+FT-DK 2010 | 60/40 | left | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T1S3DX1 | / | / | ||||||||||
SEM-Grid | T1S3DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
12 | T1S3 | Mo2 | T1S3DK2 | BPM+FT-DK 2010 | 60/30 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T1S3DX2 | / | / | ||||||||||
SEM-Grid | T1S3DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | up | ||||||||
13 | T1S4 | Mo1 | T1S4DK1 | BPM+FT-DK 2010 | 60/40 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T1S4DX1 | / | / | ||||||||||
SEM-Grid | T1S4DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | up | ||||||||
14 | T1S4 | Mo2 | T1S4DK2 | FT-DK 2020 | 40/30 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
SCR | T1S4DF2 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | ||||||||
15 | T1S4 | Mo3 | T1S4DK3 | BPM+FT-DK 2010 | 70/30 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T1S4DX2 | / | / | ||||||||||
SEM-Grid | T1S4DG3 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | up | ||||||||
IPM | T1S4DF3G | / | Detector: down and right PL: up | ||||||||||
16 | T1S4 | Mo4 | T1S4DK4 | BPM+FT-DK 2136+IPM | 50/40 | up | B013L | 6,4 | 2,3 | geplante FAIR-Beschaffung | |||
BPM | T1S4DX3 | / | / | ||||||||||
SEM-Grid | T1S4DG4 | FT-DL 2140 | 64x64x2 | FT-DG | FT-DG 2050 | up | |||||||
IPM | T1S4DF4G | / | Detector: down and right PL: up | ||||||||||
17 | T8DU | Mo1 | T8DUDK1 | BPM+FT-DK 2010+IPM | 100/50 | left, up | B013L | 6,4 | 2,3 | India Inkind | |||
BPM | T8DUDX1 | / | / | ||||||||||
SEM-Grid | T8DUDG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | Änderung Einbaurichtung wegen DMU 19-11-18 | |||||||
IPM | T8DUDF1G | / | Detector: up and right PL: left | ||||||||||
18 | TSX1 | Mo1 | TSX1DK1 | FT-DK 2040 | 50/30 | right, up | B013R* | 6,4 | 2,3 | India Inkind | |||
MWPC | TSX1DG1G | FT-DL 2010 | ø70 mm | FT-DG 2120 | up | ||||||||
SEM-Grid | TSX1DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | right | ||||||||
19 | TSX1 | Mo2 | TSX1DK2 | BPM+FT-DK 2020 | 30/30 | right, up | B013R* | 6,4 | 2,3 | India Inkind | |||
BPM | TSX1DX1 | / | / | ||||||||||
SCR | TSX1DF2 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | ||||||||
20 | TSX1 | Mo3 | TSX1DK3 | FT-DK 2040 | 30/40 | right, up | B013R* | 6,4 | 2,3 | India Inkind | |||
MWPC | TSX1DG3G | FT-DL 2010 | ø70 mm | FT-DG 2120 | up | ||||||||
SEM-Grid | TSX1DG3 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
21 | TSX1 | Mo4 | TSX1DK4 | FT-DK 2030+IPM | 50/40 | right, up | B013R* | 6,4 | 2,3 | India Inkind | |||
MWPC | TSX1DG4G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | TSX1DG4 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
IPM | TSX1DF1G | / | Detector: right and down PL: up | ||||||||||
22 | TSX1 | Mo5 | TSX1DK5 | BPM+FT-DK 2060 | 40/30 | right, up | B013R* | 6,4 | 2,3 | India Inkind | |||
BPM | TSX1DX2 | / | / | ||||||||||
MWPC | TSX1DG5G | FT-DL 2010 | ø70 mm | FT-DG 2120 | up | ||||||||
SEM-Grid | TSX1DG5 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | right | ||||||||
PDC | TSX1DI5 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | ||||||||
23 | TSF1 | Mo1 | TSF1DK1 | BPM+FT-DK 2050 | 80/20 | right, up | / | / | / | India Inkind | |||
BPM | TSF1DX1 | / | / | ||||||||||
MWPC | TSF1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
PDC | TSF1DI | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | ||||||||
24 | TSF1 | Mo2 | TSF1DK2 | FT-DK 2010 | 80/20 | right, up | / | / | / | India Inkind | |||
SEM-Grid | TSF1DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
T1F2 | no diagnostics | ||||||||||||
25 | TFF1 | Mo1 | TFF1DK1 | BPM+FT-DK 2050+IPM | 40/50 | left, up | B018L | 6,15 | 2,3 | India Inkind | |||
BPM | TFF1DX1 | / | |||||||||||
MWPC | TFF1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
PDC | TFF1DI1 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | ||||||||
SEM-Grid | TFF1DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
IPM | TFF1DF1G | / | Detector: left and down, PL: up | ||||||||||
26 | TSX2 | Mo1 | TSX2DK1 | FT-DK 2080 | ohne linken Flansch | 30/40 | right, up | B013R* | 6.4 | 2.3 | India Inkind | ||
SCR | TSX2DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | ||||||||
27 | TXL1 | Mo1 | TXL1DK1 | FT-DK 2080 | ohne linken Flansch | 45/30 | right, up | India Inkind | |||||
SCR | TXL1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | ||||||||
28 | TXL2 | Mo1 | TXL2DK1 | FT-DK 2030 | 50/30 | right, up | B013R* | 6.4 | 2.3 | India Inkind | |||
SEM-Grid | TXL2DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
MWPC | TXL2DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
29 | TXL2 | Mo2 | TXL2DK2 | FT-DK 2010 | 20/30 | right, up | B013R* | 6.4 | 2.3 | India Inkind | |||
SCR | TXL2DF2 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | ||||||||
30 | TXL2 | Mo3 | TXL2DK3 | BPM+FT-DK 2030+IPM | 50/30 | right, up | B013R* | 6.4 | 2.3 | India Inkind | |||
BPM | TXL2DX1 | / | / | ||||||||||
SEM-Grid | TXL2DG3 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
MWPC | TXL2DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
IPM | TXL2DF3G | / | PL:right | ||||||||||
31 | TXL2 | Mo4 | TXL2DK4 | FT-DK 2134+BPM | 50/30 | right, up | B013R* | 6.4 | 2.3 | FAIR-Beschaffung (with integrated BPM) | |||
SCR | TXL2DF4 | FT-DL 2230 | ø120mm | FT-DF 2020 | up | ||||||||
BPM | TXL2DX2 | ||||||||||||
32 | TXL2 | Mo5 | TXL2DK5 | FT-DK 2050 | 50/30 | right, up | B013R* | 6.4 | 2.3 | India Inkind | |||
MWPC | TXL2DG5G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
SEM-Grid | TXL2DG5 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | up against beam direction | ||||||||
PDC | TXL2DI5 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | ||||||||
33 | TXL2 | Mo6 | TXL2DK6 | BPM+FT-DK 2134+IPM | 50/30 | right, up | B013R* | 6.4 | 2.3 | FAIR-Beschaffung | |||
SCR | TXL2DG6 | FT-DL 2230 | ø120mm | FT-DF 2020 | up | ||||||||
MWPC | TXL2DG6G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | ||||||||
BPM | TXL2DX3 | ||||||||||||
IPM | TXL2DF6G | / | kein Einbauraum | ||||||||||
34 | TXL3 | Mo1 | TXL3DK1 | FT-DK 2030 | 60/30 | right, up | B013R* | 6.4 | 2.3 | India Inkind | |||
SEM-Grid | TXL3DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
MWPC | TXL3DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
35 | TXL3 | Mo2 | TXL3DK2 | BPM+FT-DK 2030+IPM | 60/30 | right, up | B013R* | 6.4 | 2.3 | India Inkind | |||
BPM | TXL3DX1 | ||||||||||||
SEM-Grid | TXL3DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
MWPC | TXL3DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
IPM | TXL3DF2G | / | Detector: left and down, PL: up | ||||||||||
36 | TXL3 | Mo3 | TXL3DK3 | FT-DK 2010 | 60/30 | right, up | B013R* | 6.4 | 2.3 | India Inkind | |||
PDC | TXL3DI3 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | ||||||||
37 | T1X1 | Mo1 | T1X1DK1 | FT-DK 2133 | 50/40 | right / left | D111R* | / | 2.3 | geolante FAIR-Beschaffung | |||
BPM | T1X1DX1 | / | |||||||||||
SEM-Grid | T1X1DG1 | FT-DL 2120 | 64x64x1,2 | FT-DG 2010 | right | ||||||||
MWPC | T1X1DG1G | FT-DL 2020 | ø70 mm | FT-DG 2120 | left | ||||||||
SCR | T1X1DF1 | FT-DL 2220 | ø100 mm | FT-DF 2011 | left | ||||||||
PDC | T1X1DI1 | FT-DL 2060 | ø100 mm | FT-DI 2020 | right | ||||||||
IPM | T1X1DF1G | / | Detector: left and up, PL: right | ||||||||||
38 | T1X1 | Mo2 | T1X1DK2 | BPM+ FT-DK 2010 | 50/40 | right | D111R* | / | 2.3 | India Inkind | |||
BPM | T1X1DX2 | / | |||||||||||
SEM-Grid | T1X1DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
39 | T1X1 | Mo3 | T1X1DK3 | FT-DK 2130 | 50/40 | right | D111R* | / | 2.3 | India Inkind | |||
MWPC | T1X1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | ||||||||
PDC | T1X1DI3 | FT-DL 2050 | ø100 mm | right | |||||||||
40 | T1X1 | Mo4 | T1X1DK4 | FT-DK 2130 | 50/40 | right | D111R* | / | 2.3 | India Inkind | |||
MWPC | T1X1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | ||||||||
SEM-Grid | T1X1DG3 | FT-DL 2130 | 64x64x2 | FT-DI 2020 | right, against beam direction | ||||||||
41 | T1X2 | Mo1 | T1X2DK1 | FT-DK 2131 | 60/20 | right | D111R* | / | 2.3 | India Inkind | |||
BPM | T1X2DX1 | / | |||||||||||
SEM-Grid | T1X2DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
MWPC | T1X2DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | ||||||||
42 | T1X2 | Mo2 | T1X2DK2 | FT-DK 2130 | 60/20 | right | D111R* | / | 2.3 | India Inkind | |||
SEM-Grid | T1X2DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
MWPC | T1X2DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | ||||||||
43 | T1X2 | Mo3 | T1X2DK3 | FT-DK 2132 | 40/50 | left | D111R* | / | 2.3 | India Inkind | |||
BPM | T1X2DX2 | / | |||||||||||
SEM-Grid | T1X2DG3 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
MWPC | T1X2DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | left | ||||||||
PDC | T1X2DI3 | FT-DL 2050 | ø100 mm | FT-DI 2010 | left | ||||||||
IPM | T1X2DF3G | / | Detector: right and up, PL: left | ||||||||||
44 | T1F1 | Mo1 | T1F1DK1 | FT-DK 2132 | 60/30 | left | D112L* | / | 2.3 | India Inkind | |||
BPM | T1F1DX1 | / | left | ||||||||||
SEM-Grid | T1F1DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
MWPC | T1F1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | left | ||||||||
PDC | T1F1DI1 | FT-DL 2050 | ø100 mm | FT-DI 2010 | left | ||||||||
45 | T1C1 | Mo1 | T1C1DK1 | FT-DK 2020 | 40/30 | left | D111R* | / | 2.3 | India Inkind | |||
SCR | T1C1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | left | ||||||||
46 | T1C1 | Mo2 | T1C1DK2 | FT-DK 2135 | 50/20 | left | D111R* | / | 2.3 | FAIR Beschaffung | |||
BPM | T1C1DX1 | ||||||||||||
MWPC | T1C1DG2G | FT-DL 2030 | ø100mm | FT-DG 2110 | left | ||||||||
SEM-Grid | T1C1DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left, against beam direction | ||||||||
47 | T1C1 | Mo3 | T1C1DK3 | FT-DK 2135 | 60/30 | left, right | D111R* | / | 2.3 | FAIR-Beschaffung | |||
MWPC | T1C1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | left | ||||||||
SEM-Grid | T1C1DG3 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left, against beam direction | ||||||||
PDC | T1C1DI3 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | ||||||||
48 | T1C2 | Mo1 | T1C2DK1 | FT-DK 2020 | 40/30 | left | D111L* | / | 2.3 | India Inkind | |||
MWPC | T1C2DG1G | FT-DL 2010 | ø70 mm | FT-DG 2120 | left | ||||||||
49 | T1C2 | Mo2 | T1C2DK2 | FT-DK-2137 | 50/20 | left | D111L* | / | 2.3 | FAIR-Beschaffung | |||
MWPC | T1C2DG2G | FT-DL 2010 | ø70 mm | FT-DG 2120 | left | ||||||||
PDC | T1C2DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | left | ||||||||
50 | T1D1 | Mo1 | T1D1DK1 | FT-DK 2020 | 50/40 | right | / | ||||||
SCR | T1D1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | right | ||||||||
51 | T1D1 | Mo2 | T1D1DK2 | FT-DK 2138 | 90/80 | right | / | 2,3 | FAIR-Beschaffung | ||||
BPM | T1D1DX1 | ||||||||||||
SEM-Grid | T1D1DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | right | ||||||||
MWPC | T1D1DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | ||||||||
PDC | T1D1DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | ||||||||
IPM | T1D1DF2G | Detector: left and up, PL: right | |||||||||||
52 | TPP1 | Mo1 | TPP1DK1 | BPM+FT-DK 2030 | 80/30 | left, up | / | / | India Inkind | ||||
BPM | TPP1DX1 | ||||||||||||
SEM-Grid | TPP1DG1 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
MWPC | TPP1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
53 | TPP1 | Mo2 | TPP1DK2 | BPM+FT-DK 2050 | 80/30 | left, up | / | / | India Inkind | ||||
BPM | TPP1DX2 | ||||||||||||
SEM-Grid | TPP1DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | left | ||||||||
MWPC | TPP1DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | ||||||||
PDC | THP1DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | ||||||||
54 | TPP2 | Mo1 | TPP2DK1 | BPM+FT-DK 2080+IPM | ohne linken Flalge | 40/40 | right, up | B013R* | / | 2,3 | India Inkind | ||
BPM | TPP2DX1 | ||||||||||||
SEM-Grid | TPP2DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
IPM | TPP2DF1G | ||||||||||||
55 | TPP2 | Mo2 | TPP2DK2 | BPM+FT-DK 2020+IPM | 40/40 | India Inkind | |||||||
BPM | TPP2DX2 | ||||||||||||
SEM-Grid | TPP2DG2 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
IPM | TPP2DF2G | ||||||||||||
56 | TPP2 | Mo3 | TPP2DK3 | FT-DK 2020 | 40/40 | India Inkind | |||||||
SEM-Grid | TPP2DG3 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
BPM | TPP2DX2 | ||||||||||||
IPM | TPP2DF2G | ||||||||||||
57 | TAP1 | Mo1 | TAP1DK1 | BPM+FT-DK 2020 | 20/25 | left, up | / | 2,3 | India Inkind | ||||
BPM | TAP1DX1 | ||||||||||||
SEM-Grid | TAP1DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
58 | TAP2 | Mo1 | TAP2DK1 | FT-DK 2020 | 60/40 | right, up | B019R | / | 2,1 | India Inkind | |||
SEM-Grid | TAP2DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
59 | TAP2 | Mo2 | TAP2DK2 | BPM+FT-DK 2010+IPM | 60/40 | right, up | B019R | / | 2,1 | India Inkind | |||
BPM | TAP2DX1 | ||||||||||||
SEM-Grid | TAP2DG2 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | up | ||||||||
IPM | TAP2DF2G | ||||||||||||
60 | TFC1 | Mo1 | TFC1DK1 | special required | 85/170 | left, up | / | / | 3,1 | geplante FAIR-Beschaffung: new design required at this position, at this position very big apertures (CF300, CF400 or bigger) are required. Further chamber details can not be given in the moment | |||
BPM | TFC1DX1 | ||||||||||||
SEM-Grid | TFC1DG1 | up | |||||||||||
61 | FRF | Mo1 | FRFDK1 | special required | 170/170 | up | geplante FAIR-Beschaffung: new design required at this position, at this position very big apertures (CF300, CF400 or bigger) are required. Further chamber details can not be given in the moment | ||||||
SEM-Grid | FRFDG1 | up | |||||||||||
62 | FRF | Mo2 | FRFDK2 | special required | 380/170 | left, up | geplante FAIR-Beschaffung: new design required at this position, at this position very big apertures (CF300, CF400 or bigger) are required. Further chamber details can not be given in the moment | ||||||
BPM | FRFDX1 | ||||||||||||
SEM-Grid | FRFDG2 | up | |||||||||||
TRR1 | no diagnostics | ||||||||||||
63 | THS1/THE1 | Mo1 | THE1DK1 | BPM+FT-DK 2020 | 40/30 | up | B012R | 6,3 | 2,2 | India Inkind | |||
BPM | THE1DX1 | ||||||||||||
SEM-Grid | THE1DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
64 | THS1/THE1 | Mo2 | THE1DK2 | FT-DK 2020 | 30/30 | right, up | B012R | 6,3 | 2,2 | India Inkind | |||
SCR | THE1DF2 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | ||||||||
65 | THS1/THE1 | Mo3 | THE1DK3 | BPM+FT-DK 2020 | 40/30 | right, up | B012R | 6,3 | 2,2 | India Inkind | |||
SEM-Grid | THE1DG3 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | ||||||||
66 | THS1/THE1 | Mo4 | THE1DK4 | BPM+FT-DK 2020 | 20/30 | right, up | B012R | 6,3 | 2,2 | India Inkind | |||
BPM | THE1DX2 | ||||||||||||
SCR | THE1DF4 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | ||||||||
67 | THS1/THE1 | Mo5 | THE1DK5 | BPM+FT-DK 2020 | 40/30 | right, up | B012R | 6,3 | 2,2 | India Inkind | |||
SCR | THE1DF5 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | ||||||||
68 | THS1/THE1 | Mo6 | THE1DK6 | BPM+FT-DK 2010 | 90/10 | up | B012R | 6,3 | 2,2 | India Inkind | |||
BPM | THE1DX3 | ||||||||||||
SEM-Grid | THE1DG6 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | up | ||||||||
69 | THS1/THE1 | Mo7 | THE1DK7 | BPM+FT-DK 2010 | 60/10 | up | B012R | 6,3 | 2,2 | India Inkind | |||
BPM | THE1DX4 | ||||||||||||
SEM-Grid | THE1DG7 | FT-DL 2130 | 64x64x2 | FT-DG 2040 | up | ||||||||
70 | TNC1 | Mo1 | TNC1DK1 | FT-DK 2030 | 80/50 | India Inkind | |||||||
MWPC | TNC1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | |||||||||
PDC | TNC1DI1 | FT-DL 2050 | FT-DI 2010 | ||||||||||
71 | TNC1 | Mo2 | TNC1DK2 | special required | 140/100 | geplante FAIR-Beschaffung:new design required at this position, Entry and Exit Flanges 2xCF200, Flange for vacuum pump: 1xCF150, Flange for vacuum measurements: 2xCF40 Flange for detector: CF250 | |||||||
SCR | TNC1DF2 | ||||||||||||
Inkind Indien | |||||||||||||
Chamber Type | Number | Inkind Indien | FAIR-Beschaffung | geplante FAIR-Beschaffung | standard | FAIR Beschaffung | |||||||
FT-DK 2010 | 14 | 14 | special solutions | geplante FAIR-Beschaffung | |||||||||
FT-DK 2020 | 14 | 14 | ausheizbar, nicht Indien | ausheizbar geplante FAIR-Beschaffung | |||||||||
FT-DK 2030 | 10 | 10 | Konstruktion ausstehend geplante FAIR-Beschaffung | ||||||||||
FT-DK 2040 | 2 | 2 | |||||||||||
FT-DK 2050 | 6 | 6 | |||||||||||
FT-DK 2060 | 1 | 1 | |||||||||||
FT-DK 2070 | 2 | 2 | |||||||||||
FT-DK 2080 | 3 | 3 | |||||||||||
FT-DK 2130 | 3 | 3 | |||||||||||
FT-DK 2131 | 1 | 1 | |||||||||||
FT-DK 2132 | 2 | 2 | |||||||||||
FT-DK 2133 | 1 | 1 | |||||||||||
FT-DK 2134 | 2 | 2 | |||||||||||
FT-DK 2135 | 2 | 2 | |||||||||||
FT-DK 2136 | 1 | 1 | |||||||||||
FT-DK 2137 | 1 | 1 | |||||||||||
FT-DK 2138 | 1 | 1 | |||||||||||
tbd | 5 | 5 | |||||||||||
Total | 71 | 58 | 6 | 7 | |||||||||
Detektor | Antrieb | Anzahl | Inkind Slowenien | Differenz | |||||||||
MWPC klein | FT-DL 2010 | 5 | 16 | 11 | |||||||||
MWPC klein ausheizbar | FT-DL 2020 | 1 | 2 | 1 | |||||||||
MWPC groß | FT-DL 2030 | 27 | 16 | -11 | |||||||||
PDC | FT-DL 2050 | 15 | 15 | 0 | |||||||||
PDC ausheizbar | FT-DL 2060 | 1 | 1 | 0 | |||||||||
PG klein | FT-DL 2110 | 10 | 20 | 10 | |||||||||
PG klein ausheizbar | FT-DL 2120 | 1 | 2 | 1 | |||||||||
PG groß | FT-DL 2130 | 33 | 24 | -9 | |||||||||
PG groß ausheizbar | FT-DL 2140 | 1 | 0 | -1 | |||||||||
SC klein | FT-DL 2210 | 9 | 7 | -2 | |||||||||
SC klein ausheizbar | FT-DL 2220 | 1 | 1 | 0 | |||||||||
SC groß | FT-DL 2230 | 7 | 8 | 1 | |||||||||
SC groß ausheizbar | FT-DL 2240 | 0 | 0 | 0 | |||||||||
Summe | 111 | 112 | 1 | ||||||||||
PG groß ausheizbar SIS-100 | FT-DL 2140 | 6 | 6 | 0 | |||||||||
SC groß ausheizbar SIS-100 | FT-DL 2240 | 2 | 2 | 0 | |||||||||
Summe | 8 | 8 | 0 |