ID | Beam Line | Chamber | Nomen- clature | Chamber Type | Linear Actuator Type | Detector Active Area | Detector Type | Envelops [mm/mm] | Installation Direction | HEBT | SIS18 Transfer | Remarks: |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | T1S1 | Mo1 | T1S1DK1 | special required | 30/50 | left, up | A | APPA, Dump, SFRS | geplante FAIR-Beschaffung: at this position new design is required. Design of foil stripper needed first! ⇒S. Zeller! SEM-Grid, MWPC, PDC and Foil Stripper shall be installed, Entry and Exit Flanges 2xCF150, Flange for vacuum pump: 1xCF150, Flange for vacuum measurements: 2xCF40 Flange for detector: 3xCF200, Flange for Foil Stripper: tbd | |||
MWPC | T1S1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | APPA, Dump, SFRS | |||||
SEM-Grid | T1S1DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | APPA, Dump, SFRS | |||||
PDC | T1S1DI1 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | A | APPA, Dump, SFRS | |||||
2 | T1S1 | Mo2 | T1S1DK2 | BPM+FT-DK 2070+BIF | 30/30 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
BPM | T1S1DX1 | / | / | A | APPA, Dump, SFRS | |||||||
SCR | T1S1DF2 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | A | APPA, Dump, SFRS | |||||
IPM | T1S1DF2G | / | Detector: up and right, PL: left | A | APPA, Dump, SFRS | |||||||
3 | T1S1 | Mo3 | T1S1DK3 | FT-DK 2070 | 60/50 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
SCR | T1S1DF3 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | A | APPA, Dump, SFRS | |||||
4 | T1S1 | Mo4 | T1S1DK4 | FT-DK 2030 | 60/30 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
MWPC | T1S1DG4G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | APPA, Dump, SFRS | |||||
SEM-Grid | T1S1DG4 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | APPA, Dump, SFRS | |||||
5 | T1S1 | Mo5 | T1S1DK5 | FT-DK 2010 | 50/30 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
SCR | T1S1DF5 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | A | APPA, Dump, SFRS | |||||
6 | T1S1 | Mo6 | T1S1DK6 | BPM+FT-DK 2010 | 50/40 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
BPM | T1S1DX2 | / | / | A | APPA, Dump, SFRS | |||||||
SCR | T1S1DF6 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | A | APPA, Dump, SFRS | |||||
7 | T1S1 | Mo7 | T1S1DK7 | FT-DK 2030 | 50/50 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
MWPC | T1S1DG7G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | APPA, Dump, SFRS | |||||
SEM-Grid | T1S1DG7 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | APPA, Dump, SFRS | |||||
8 | T1S1 | Mo8 | T1S1DK8 | BPM+FT-DK 2050 | 80/40 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
BPM | T1S1DX3 | / | / | A | APPA, Dump, SFRS | |||||||
MWPC | T1S1DG8G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | APPA, Dump, SFRS | |||||
SEM-Grid | T1S1DG8 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | APPA, Dump, SFRS | |||||
PDC | T1S1DI8 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | A | APPA, Dump, SFRS | |||||
9 | T1S2 | Mo1 | T1S2DK1 | BPM+FT-DK 2030 | 50/60 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
BPM | T1S2DX1 | / | / | A | APPA, Dump, SFRS | |||||||
MWPC | T1S2DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | APPA, Dump, SFRS | |||||
SEM-Grid | T1S2DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | APPA, Dump, SFRS | |||||
10 | T1S2 | Mo2 | T1S2DK2 | BPM+FT-DK 2050+BIF | 50/30 | left, up | A | APPA, Dump, SFRS | India Inkind | |||
BPM | T1S2DX2 | / | / | A | APPA, Dump, SFRS | |||||||
MWPC | T1S2DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | APPA, Dump, SFRS | |||||
SEM-Grid | T1S2DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | APPA, Dump, SFRS | |||||
PDC | T1S2DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | A | APPA, Dump, SFRS | |||||
IPM | T1S2DF2G | / | Detector: up and right PL: left | A | APPA, Dump, SFRS | |||||||
11 | T1S3 | Mo1 | T1S3DK1 | BPM+FT-DK 2010 | 60/40 | left | A | Dump, SIS100 | India Inkind | |||
BPM | T1S3DX1 | / | / | A | Dump, SIS100 | |||||||
SEM-Grid | T1S3DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | Dump, SIS100 | |||||
12 | T1S3 | Mo2 | T1S3DK2 | BPM+FT-DK 2010 | 60/30 | left, up | A | Dump, SIS100 | India Inkind | |||
BPM | T1S3DX2 | / | / | A | Dump, SIS100 | |||||||
SEM-Grid | T1S3DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up | A | Dump, SIS100 | |||||
13 | T1S4 | Mo1 | T1S4DK1 | BPM+FT-DK 2010 | 60/40 | left, up | A | SIS100 | India Inkind | |||
BPM | T1S4DX1 | / | / | A | SIS100 | |||||||
SEM-Grid | T1S4DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up | A | SIS100 | |||||
14 | T1S4 | Mo2 | T1S4DK2 | FT-DK 2020 | 40/30 | left, up | A | SIS100 | India Inkind | |||
SCR | T1S4DF2 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | A | SIS100 | |||||
15 | T1S4 | Mo3 | T1S4DK3 | BPM+FT-DK 2010 | 70/30 | left, up | A | SIS100 | India Inkind | |||
BPM | T1S4DX2 | / | / | A | SIS100 | |||||||
SEM-Grid | T1S4DG3 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up | A | SIS100 | |||||
IPM | T1S4DF3G | / | Detector: down and right PL: up | A | SIS100 | aus T1S4DK4 | ||||||
16 | T1S4 | Mo4 | T1S4DK4 | BPM+FT-DK 2136+BIF | 50/40 | up | A | SIS100 | FAIR-Beschaffung | |||
BPM | T1S4DX3 | / | / | A | SIS100 | |||||||
SEM-Grid | T1S4DG4 | FT-DL 2140 | 64x64x1,8 | FT-DG | FT-DG 2050 | up | A | SIS100 | ||||
IPM | T1S4DF4G | / | Detector: down and right PL: up | A | SIS100 | |||||||
17 | T8DU | Mo1 | T8DUDK1 | BPM+FT-DK 2010+BIF | 100/50 | left, up | A | Dump | India Inkind Achtung: Dump-Grube, früher Einbau | |||
BPM | T8DUDX1 | / | / | A | Dump | |||||||
SEM-Grid | T8DUDG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | Dump | Änderung Einbaurichtung wegen DMU 19-11-18 | ||||
IPM | T8DUDF1G | / | Detector: up and right PL: left | A | Dump | |||||||
18 | TSX1 | Mo1 | TSX1DK1 | FT-DK 2040 | 50/30 | right, up | A | APPA, SFRS | India Inkind | |||
MWPC | TSX1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2120 | up | A | APPA, SFRS | |||||
SEM-Grid | TSX1DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | right | A | APPA, SFRS | |||||
19 | TSX1 | Mo2 | TSX1DK2 | BPM+FT-DK 2020 | 30/30 | right, up | A | APPA, SFRS | India Inkind | |||
BPM | TSX1DX1 | / | / | A | APPA, SFRS | |||||||
SCR | TSX1DF2 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | A | APPA, SFRS | |||||
20 | TSX1 | Mo3 | TSX1DK3 | FT-DK 2040 | 30/40 | right, up | A | APPA, SFRS | India Inkind | |||
MWPC | TSX1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2120 | up | A | APPA, SFRS | |||||
SEM-Grid | TSX1DG3 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | A | APPA, SFRS | |||||
21 | TSX1 | Mo4 | TSX1DK4 | FT-DK 2030+BIF | 50/40 | right, up | A | APPA, SFRS | India Inkind | |||
MWPC | TSX1DG4G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | APPA, SFRS | |||||
SEM-Grid | TSX1DG4 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | A | APPA, SFRS | |||||
IPM | TSX1DF1G | / | Detector: right and down PL: up | A | APPA, SFRS | |||||||
22 | TSX1 | Mo5 | TSX1DK5 | BPM+FT-DK 2060 | 40/30 | right, up | A | APPA, SFRS | India Inkind | |||
BPM | TSX1DX2 | / | / | A | APPA, SFRS | |||||||
MWPC | TSX1DG5G | FT-DL 2030 | ø100 mm | FT-DG 2120 | up | A | APPA, SFRS | |||||
SEM-Grid | TSX1DG5 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | right | A | APPA, SFRS | |||||
PDC | TSX1DI5 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | A | APPA, SFRS | |||||
23 | TSF1 | Mo1 | TSF1DK1 | BPM+FT-DK 2050 | 80/20 | right, up | A | SFRS | India Inkind | |||
BPM | TSF1DX1 | / | / | A | SFRS | |||||||
MWPC | TSF1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | SFRS | |||||
PDC | TSF1DI | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | A | SFRS | |||||
24 | TSF1 | Mo2 | TSF1DK2 | FT-DK 2010 | 80/20 | right, up | A | SFRS | India Inkind | |||
SEM-Grid | TSF1DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | A | SFRS | |||||
T1F2 | no diagnostics | |||||||||||
25 | TFF1 | Mo1 | TFF1DK1 | BPM+FT-DK 2050+BIF | 40/50 | left, up | A | SFRS | India Inkind | |||
BPM | TFF1DX1 | / | A | SFRS | ||||||||
MWPC | TFF1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | A | SFRS | |||||
PDC | TFF1DI1 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | A | SFRS | |||||
SEM-Grid | TFF1DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | A | SFRS | |||||
IPM | TFF1DF1G | / | Detector: left and down, PL: up | A | SFRS | |||||||
26 | TSX2 | Mo1 | TSX2DK1 | FT-DK 2080 | ohne linken Flansch | 30/40 | right, up | B | APPA | India Inkind | ||
SCR | TSX2DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | B | APPA | |||||
27 | TXL1 | Mo1 | TXL1DK1 | FT-DK 2080 | ohne linken Flansch | 45/30 | right, up | B | India Inkind | |||
SCR | TXL1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | B | ||||||
28 | TXL2 | Mo1 | TXL2DK1 | FT-DK 2030 | 50/30 | right, up | B | APPA | India Inkind | |||
SEM-Grid | TXL2DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | B | APPA | |||||
MWPC | TXL2DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | B | APPA | |||||
29 | TXL2 | Mo2 | TXL2DK2 | FT-DK 2010 | 20/30 | right, up | B | APPA | India Inkind | |||
SCR | TXL2DF2 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | B | APPA | |||||
30 | TXL2 | Mo3 | TXL2DK3 | BPM+FT-DK 2030+BIF | 50/30 | right, up | B | APPA | India Inkind | |||
BPM | TXL2DX1 | / | / | B | APPA | |||||||
SEM-Grid | TXL2DG3 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | B | APPA | |||||
MWPC | TXL2DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | B | APPA | |||||
IPM | TXL2DF3G | / | PL:right | B | APPA | |||||||
31 | TXL2 | Mo4 | TXL2DK4 | FT-DK 2134+BPM | 50/30 | right, up | B | APPA | FAIR-Beschaffung (with integrated BPM) | |||
SCR | TXL2DF4 | FT-DL 2230 | ø120mm | FT-DF 2020 | up | B | APPA | |||||
BPM | TXL2DX2 | B | APPA | |||||||||
32 | TXL2 | Mo5 | TXL2DK5 | FT-DK 2050 | 50/30 | right, up | B | APPA | India Inkind | |||
MWPC | TXL2DG5G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | B | APPA | |||||
SEM-Grid | TXL2DG5 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up against beam direction | B | APPA | |||||
PDC | TXL2DI5 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | B | APPA | |||||
33 | TXL2 | Mo6 | TXL2DK6 | BPM+FT-DK 2134+BIF | 50/30 | right, up | B | APPA | FAIR-Beschaffung | |||
SEM-Grid | TXL2DG6 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up | B | APPA | |||||
MWPC | TXL2DG6G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | B | APPA | |||||
BPM | TXL2DX3 | B | APPA | |||||||||
IPM | TXL2DF6G | / | B | APPA | kein Einbauraum | |||||||
34 | TXL3 | Mo1 | TXL3DK1 | FT-DK 2030 | 60/30 | right, up | B | APPA | India Inkind | |||
SEM-Grid | TXL3DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | B | APPA | |||||
MWPC | TXL3DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | B | APPA | |||||
35 | TXL3 | Mo2 | TXL3DK2 | BPM+FT-DK 2030+BIF | 60/30 | right, up | B | APPA | India Inkind | |||
BPM | TXL3DX1 | B | APPA | |||||||||
SEM-Grid | TXL3DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | B | APPA | |||||
MWPC | TXL3DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | B | APPA | |||||
IPM | TXL3DF2G | / | Detector: left and down, PL: up | B | APPA | |||||||
36 | TXL3 | Mo3 | TXL3DK3 | FT-DK 2010 | 60/30 | right, up | B | APPA | India Inkind | |||
PDC | TXL3DI3 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | B | APPA | |||||
37 | T1X1 | Mo1 | T1X1DK1 | FT-DK 2133 | 50/40 | right / left | A | FAIR-Beschaffung | ||||
BPM | T1X1DX1 | / | A | |||||||||
SEM-Grid | T1X1DG1 | FT-DL 2120 | 64x64x1,2 | FT-DG 2010 | right | A | ||||||
MWPC | T1X1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2120 | left | A | ||||||
SCR | T1X1DF1 | FT-DL 2220 | ø100 mm | FT-DF 2011 | left | A | ||||||
PDC | T1X1DI1 | right | A | moved to DK3 | ||||||||
IPM | T1X1DF1G | / | Detector: left and up, PL: right | A | ||||||||
38 | T1X1 | Mo2 | T1X1DK2 | BPM+ FT-DK 2010 | 50/40 | right | A | India Inkind | ||||
BPM | T1X1DX2 | / | A | |||||||||
SEM-Grid | T1X1DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | A | ||||||
39 | T1X1 | Mo3 | T1X1DK3 | FT-DK 2130 | 50/40 | right | A | India Inkind | ||||
MWPC | T1X1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | A | ||||||
PDC | T1X1DI3 | FT-DL 2050 | ø100 mm | right | A | |||||||
40 | T1X1 | Mo4 | T1X1DK4 | FT-DK 2130 | 50/40 | right | A | India Inkind | ||||
MWPC | T1X1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | A | ||||||
SEM-Grid | T1X1DG3 | FT-DL 2130 | 64x64x1,8 | FT-DI 2020 | right, against beam direction | A | ||||||
41 | T1X2 | Mo1 | T1X2DK1 | FT-DK 2131 | 60/20 | right | B | India Inkind Achtung: Schräge Ebene (C. Englert) | ||||
BPM | T1X2DX1 | / | B | |||||||||
SEM-Grid | T1X2DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | B | ||||||
MWPC | T1X2DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | B | ||||||
42 | T1X2 | Mo2 | T1X2DK2 | FT-DK 2130 | 60/20 | right | B | India Inkind Achtung: Gestell G004 (C. Englert) | ||||
SEM-Grid | T1X2DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | B | ||||||
MWPC | T1X2DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | B | ||||||
43 | T1X2 | Mo3 | T1X2DK3 | FT-DK 2132 | 40/50 | left | B | India Inkind | ||||
BPM | T1X2DX2 | / | B | |||||||||
SEM-Grid | T1X2DG3 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | B | ||||||
MWPC | T1X2DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | left | B | ||||||
PDC | T1X2DI3 | FT-DL 2050 | ø100 mm | FT-DI 2010 | left | B | ||||||
IPM | T1X2DF3G | / | Detector: right and up, PL: left | B | ||||||||
44 | T1F1 | Mo1 | T1F1DK1 | FT-DK 2132 | 60/30 | left | B | India Inkind | ||||
BPM | T1F1DX1 | / | left | B | ||||||||
SEM-Grid | T1F1DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | B | ||||||
MWPC | T1F1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | left | B | ||||||
PDC | T1F1DI1 | FT-DL 2050 | ø100 mm | FT-DI 2010 | left | B | ||||||
45 | T1C1 | Mo1 | T1C1DK1 | FT-DK 2020 | 40/30 | left | A | India Inkind Achtung: Schräge Ebene (C. Englert) | ||||
SCR | T1C1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | left | A | ||||||
46 | T1C1 | Mo2 | T1C1DK2 | FT-DK 2135 | 50/20 | left | A | FAIR Beschaffung Achtung: Schräge Ebene (C. Englert) | ||||
BPM | T1C1DX1 | A | ||||||||||
MWPC | T1C1DG2G | FT-DL 2030 | ø100mm | FT-DG 2110 | left | A | ||||||
SEM-Grid | T1C1DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left, against beam direction | A | ||||||
47 | T1C1 | Mo3 | T1C1DK3 | FT-DK 2135 | 60/30 | left, right | A | FAIR-Beschaffung Achtung: Gestell G004 (C. Englert) | ||||
MWPC | T1C1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | left | A | ||||||
SEM-Grid | T1C1DG3 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left, against beam direction | A | ||||||
PDC | T1C1DI3 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | A | ||||||
48 | T1C2 | Mo1 | T1C2DK1 | FT-DK 2020 | 40/30 | left | A | India Inkind Achtung: Gestell G004 (C. Englert) | ||||
MWPC | T1C2DG1G | FT-DL 2030 | ø100 mm | FT-DG 2120 | left | A | ||||||
49 | T1C2 | Mo2 | T1C2DK2 | FT-DK 2137 | 50/20 | left | A | FAIR-Beschaffung | ||||
MWPC | T1C2DG2G | FT-DL 2030 | ø100 mm | FT-DG 2120 | left | A | ||||||
PDC | T1C2DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | left | A | ||||||
50 | T1D1 | Mo1 | T1D1DK1 | FT-DK 2020 | 50/40 | right | A | India Inkind Achtung: Gestell G004 (C. Englert) | ||||
SCR | T1D1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | right | A | ||||||
51 | T1D1 | Mo2 | T1D1DK2 | FT-DK 2138 | 90/80 | right | A | FAIR-Beschaffung | ||||
BPM | T1D1DX1 | A | ||||||||||
SEM-Grid | T1D1DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | right | A | ||||||
MWPC | T1D1DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | right | A | ||||||
PDC | T1D1DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | A | ||||||
IPM | T1D1DF2G | Detector: left and up, PL: right | A | |||||||||
52 | TPP1 | Mo1 | TPP1DK1 | BPM+FT-DK 2030 | 80/30 | left, up | B | India Inkind | ||||
BPM | TPP1DX1 | B | ||||||||||
SEM-Grid | TPP1DG1 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | B | ||||||
MWPC | TPP1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | B | ||||||
53 | TPP1 | Mo2 | TPP1DK2 | BPM+FT-DK 2050 | 80/30 | left, up | B | India Inkind | ||||
BPM | TPP1DX2 | B | ||||||||||
SEM-Grid | TPP1DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | B | ||||||
MWPC | TPP1DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | B | ||||||
PDC | THP1DI2 | FT-DL 2050 | ø100 mm | FT-DI 2010 | up | B | ||||||
54 | TPP2 | Mo1 | TPP2DK1 | BPM+FT-DK 2080+BIF | ohne linken Flalge | 40/40 | right, up | B | India Inkind | |||
BPM | TPP2DX1 | B | ||||||||||
SEM-Grid | TPP2DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | B | ||||||
IPM | TPP2DF1G | B | ||||||||||
55 | TPP2 | Mo2 | TPP2DK2 | BPM+FT-DK 2020+BIF | 40/40 | B | India Inkind | |||||
BPM | TPP2DX2 | B | eliminated | |||||||||
SEM-Grid | TPP2DG2 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | B | ||||||
IPM | TPP2DF2G | B | eliminated | |||||||||
56 | TPP2 | Mo3 | TPP2DK3 | FT-DK 2020 | 40/40 | B | India Inkind | |||||
SEM-Grid | TPP2DG3 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | B | ||||||
BPM | TPP2DX2 | B | ||||||||||
IPM | TPP2DF2G | B | ||||||||||
57 | TAP1 | Mo1 | TAP1DK1 | BPM+FT-DK 2020 | 20/25 | left, up | C | India Inkind | ||||
BPM | TAP1DX1 | C | ||||||||||
SEM-Grid | TAP1DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | C | ||||||
58 | TAP2 | Mo1 | TAP2DK1 | FT-DK 2020 | 60/40 | right, up | C | India Inkind | ||||
SEM-Grid | TAP2DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | C | ||||||
59 | TAP2 | Mo2 | TAP2DK2 | BPM+FT-DK 2010+BIF | 60/40 | right, up | C | India Inkind | ||||
BPM | TAP2DX1 | C | ||||||||||
SEM-Grid | TAP2DG2 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up | C | ||||||
IPM | TAP2DF2G | C | ||||||||||
60 | TFC1 | Mo1 | TFC1DK1 | BINP chamber | 85/170 | left, up | C | geplante FAIR-Beschaffung: BINP TCR1 (CF400) | ||||
BPM | TFC1DX1 | ø400×200 mm | BINP TCR1 type | C | ||||||||
SCR | TFC1DF1 | ø400×200 mm | BINP TCR1 type | up | C | |||||||
61 | FREX | Mo1 | FRFDK1 | BINP chamber | 380/170 | left, up | C | geplante FAIR-Beschaffung: BINP TCR1 (CF400) | ||||
BPM | FRFDX1 | ø400×200 mm | BINP TCR1 type | C | ||||||||
SCR | FRFDF1 | ø400×200 mm | BINP TCR1 type | up | C | |||||||
TRR1 | no diagnostics | |||||||||||
62 | THS1/THE1 | Mo1 | THE1DK1 | BPM+FT-DK 2020 | 40/30 | up | C | India Inkind | ||||
BPM | THE1DX1 | C | ||||||||||
SEM-Grid | THE1DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | C | ersetzen durch SCR | |||||
63 | THS1/THE1 | Mo2 | THE1DK2 | FT-DK 2020 | 30/30 | right, up | C | India Inkind | ||||
SCR | THE1DF2 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | C | ||||||
64 | THS1/THE1 | Mo3 | THE1DK3 | BPM+FT-DK 2020 | 40/30 | right, up | C | India Inkind | ||||
SEM-Grid | THE1DG3 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | C | ersetzen durch SCR | |||||
65 | THS1/THE1 | Mo4 | THE1DK4 | BPM+FT-DK 2020 | 20/30 | right, up | C | India Inkind | ||||
BPM | THE1DX2 | C | ||||||||||
SCR | THE1DF4 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | C | ||||||
66 | THS1/THE1 | Mo5 | THE1DK5 | BPM+FT-DK 2020 | 40/30 | right, up | C | India Inkind | ||||
SCR | THE1DF5 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | C | ||||||
67 | THS1/THE1 | Mo6 | THE1DK6 | BPM+FT-DK 2010 | 90/10 | up | C | India Inkind | ||||
BPM | THE1DX3 | C | in AtB9.7 später vor QS17 | |||||||||
SEM-Grid | THE1DG6 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up | C | ersetzen durch SCR | |||||
68 | THS1/THE1 | Mo7 | THE1DK7 | BPM+FT-DK 2010 | 60/10 | up | C | India Inkind | ||||
BPM | THE1DX4 | C | ||||||||||
SEM-Grid | THE1DG7 | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | up | C | ersetzen durch SCR | |||||
69 | TNC1 | Mo1 | TNC1DK1 | FT-DK 2030 | 80/50 | C | India Inkind | |||||
MWPC | TNC1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | C | ||||||
PDC | TNC1DI1 | FT-DL 2050 | FT-DI 2010 | right | C | |||||||
70 | TNC1 | Mo2 | TNC1DK2 | special required | 140/100 | C | geplante FAIR-Beschaffung:new design required at this position, Entry and Exit Flanges 2xCF200, Flange for vacuum pump: 1xCF150, Flange for vacuum measurements: 2xCF40 Flange for detector: CF250 | |||||
SCR | TNC1DF2 | C | ||||||||||
71 | TNC1 | Mo3 | TNC1DK3 | FT-DK 2050 | C | |||||||
MWPC | TNC1DG3G | FT-DL 2030 | ø100 mm | FT-DG 2110 | up | C | ||||||
PDC | TNC1DI3 | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | C | ||||||
72 | TNC1 | Mo4 / HADES | TNC1DK4 | FT-DK 2030 | C | XCBMDK1 ??? | ||||||
SCR | TNC1DF4 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | C | ||||||
73 | TNC1 | Mo5 / CBM | TNC1DK5 | FT-DK 2030 | C | XCBMDK2 ??? | ||||||
SCR | TNC1DF5 | FT-DL 2230 | ø120 mm | FT-DF 2020 | up | C | ||||||
74 | TSN1 | Mo1 | TSN1DK1 | FT-DK 2020 | C | |||||||
SCR | TSN1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | C | ||||||
75 | TSN1 | Mo2 | TSN1DK2 | FT-DK 2020 | C | |||||||
SEM-Grid | TSN1DG2 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | C | ||||||
76 | TSN1 | Mo3 | TSN1DK3 | FT-DK 2020 | C | |||||||
SCR | TSN1DF3 | FT-DL 2210 | ø100 mm | FT-DF 2010 | up | C | ||||||
77 | TSR1 | Mo1 | TSR1DK1 | FT-DK 2020 | C | |||||||
SEM-Grid | TSR1DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | up | C | ||||||
78 | XAP1 | Mo1 | XAP1DK1 | FT-DK 2050 | B | APPA | ||||||
MWPC | XAP1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | tof front | B | APPA | |||||
PDC | XAP1DI1I | FT-DL 2050 | ø100 mm | FT-DI 2010 | top back | B | APPA | |||||
SCR | XAP1DF1 | FT-DL 2230 | ø120 mm | FT-DF 2020 | right | B | APPA | |||||
SEM-Grid | XAP1DG1G | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | B | APPA | |||||
79 | XAPD | Mo1 | XAPDDK1 | FT-DK 2030 | B | APPA | ||||||
MWPC | XAPDDG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | tof front | B | APPA | |||||
SCR | XAPDDF1 | FT-DL 2230 | ø120 mm | FT-DF 2020 | right/left | B | APPA | |||||
80 | XBM1 | Mo1 | XBM1DK1 | FT-DK 2060 | B | APPA | left port blocked by dipole! | |||||
MWPC | XBM1DG1G | FT-DL 2030 | ø100 mm | FT-DG 2110 | tof front | B | APPA | |||||
SCR | XBM1DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | top back | B | APPA | |||||
PDC | XBM1DI1I | FT-DL 2050 | ø100 mm | FT-DI 2010 | right | B | APPA | |||||
81 | XBM1 | Mo2 | XBM1DK2 | FT-DK 2050 | B | APPA | ||||||
MWPC | XBM1DG2G | FT-DL 2030 | ø100 mm | FT-DG 2110 | tof front | B | APPA | |||||
SCR | XBM1DF2 | FT-DL 2230 | ø120 mm | FT-DF 2020 | right | B | APPA | |||||
PDC | XBM1DI2I | FT-DL 2050 | ø100 mm | FT-DI 2010 | top back | B | APPA | |||||
SEM-Grid | XBM1DG2G | FT-DL 2130 | 64x64x1,8 | FT-DG 2040 | left | B | APPA | |||||
82 | XPP2 | Mo1 | XPP2DK1 | FT-DK 2020 | B | APPA | ||||||
SCR | XPP2DF1 | FT-DL 2210 | ø100 mm | FT-DF 2010 | top | B | APPA | |||||
SEM-Grid | XPP2DG1 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | left/right | B | APPA | |||||
83 | XPP2 | Mo2 | XPP2DK2 | FT-DK 2020 | B | APPA | ||||||
SCR | XPP2DF2 | FT-DL 2210 | ø100 mm | FT-DF 2010 | top | B | APPA | |||||
SEM-Grid | XPP2DG2 | FT-DL 2110 | 64x64x1,2 | FT-DG 2000 | left/right | B | APPA |