User Tools

Site Tools


playground:playground:test_table
ID Beam Line Chamber Nomen- clature Chamber Type Linear Actuator Type Detector Active Area Detector Type Envelops [mm/mm] Installation Direction HEBT SIS18 Transfer Remarks:
1 T1S1 Mo1 T1S1DK1 special required 30/50 left, up A APPA, Dump, SFRS geplante FAIR-Beschaffung: at this position new design is required. Design of foil stripper needed first! ⇒S. Zeller! SEM-Grid, MWPC, PDC and Foil Stripper shall be installed, Entry and Exit Flanges 2xCF150, Flange for vacuum pump: 1xCF150, Flange for vacuum measurements: 2xCF40 Flange for detector: 3xCF200, Flange for Foil Stripper: tbd
MWPC T1S1DG1G FT-DL 2030 ø100 mm FT-DG 2110 up A APPA, Dump, SFRS
SEM-Grid T1S1DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 left A APPA, Dump, SFRS
PDC T1S1DI1 FT-DL 2050 ø100 mm FT-DI 2010 up A APPA, Dump, SFRS
2 T1S1 Mo2 T1S1DK2 BPM+FT-DK 2070+BIF 30/30 left, up A APPA, Dump, SFRS India Inkind
BPM T1S1DX1 / / A APPA, Dump, SFRS
SCR T1S1DF2 FT-DL 2230 ø120 mm FT-DF 2020 up A APPA, Dump, SFRS
IPM T1S1DF2G / Detector: up and right, PL: left A APPA, Dump, SFRS
3 T1S1 Mo3 T1S1DK3 FT-DK 2070 60/50 left, up A APPA, Dump, SFRS India Inkind
SCR T1S1DF3 FT-DL 2230 ø120 mm FT-DF 2020 up A APPA, Dump, SFRS
4 T1S1 Mo4 T1S1DK4 FT-DK 2030 60/30 left, up A APPA, Dump, SFRS India Inkind
MWPC T1S1DG4G FT-DL 2030 ø100 mm FT-DG 2110 up A APPA, Dump, SFRS
SEM-Grid T1S1DG4 FT-DL 2130 64x64x1,8 FT-DG 2040 left A APPA, Dump, SFRS
5 T1S1 Mo5 T1S1DK5 FT-DK 2010 50/30 left, up A APPA, Dump, SFRS India Inkind
SCR T1S1DF5 FT-DL 2230 ø120 mm FT-DF 2020 up A APPA, Dump, SFRS
6 T1S1 Mo6 T1S1DK6 BPM+FT-DK 2010 50/40 left, up A APPA, Dump, SFRS India Inkind
BPM T1S1DX2 / / A APPA, Dump, SFRS
SCR T1S1DF6 FT-DL 2230 ø120 mm FT-DF 2020 up A APPA, Dump, SFRS
7 T1S1 Mo7 T1S1DK7 FT-DK 2030 50/50 left, up A APPA, Dump, SFRS India Inkind
MWPC T1S1DG7G FT-DL 2030 ø100 mm FT-DG 2110 up A APPA, Dump, SFRS
SEM-Grid T1S1DG7 FT-DL 2130 64x64x1,8 FT-DG 2040 left A APPA, Dump, SFRS
8 T1S1 Mo8 T1S1DK8 BPM+FT-DK 2050 80/40 left, up A APPA, Dump, SFRS India Inkind
BPM T1S1DX3 / / A APPA, Dump, SFRS
MWPC T1S1DG8G FT-DL 2030 ø100 mm FT-DG 2110 up A APPA, Dump, SFRS
SEM-Grid T1S1DG8 FT-DL 2130 64x64x1,8 FT-DG 2040 left A APPA, Dump, SFRS
PDC T1S1DI8 FT-DL 2050 ø100 mm FT-DI 2010 up A APPA, Dump, SFRS
9 T1S2 Mo1 T1S2DK1 BPM+FT-DK 2030 50/60 left, up A APPA, Dump, SFRS India Inkind
BPM T1S2DX1 / / A APPA, Dump, SFRS
MWPC T1S2DG1G FT-DL 2030 ø100 mm FT-DG 2110 up A APPA, Dump, SFRS
SEM-Grid T1S2DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 left A APPA, Dump, SFRS
10 T1S2 Mo2 T1S2DK2 BPM+FT-DK 2050+BIF 50/30 left, up A APPA, Dump, SFRS India Inkind
BPM T1S2DX2 / / A APPA, Dump, SFRS
MWPC T1S2DG2G FT-DL 2030 ø100 mm FT-DG 2110 up A APPA, Dump, SFRS
SEM-Grid T1S2DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 left A APPA, Dump, SFRS
PDC T1S2DI2 FT-DL 2050 ø100 mm FT-DI 2010 up A APPA, Dump, SFRS
IPM T1S2DF2G / Detector: up and right PL: left A APPA, Dump, SFRS
11 T1S3 Mo1 T1S3DK1 BPM+FT-DK 2010 60/40 left A Dump, SIS100 India Inkind
BPM T1S3DX1 / / A Dump, SIS100
SEM-Grid T1S3DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 left A Dump, SIS100
12 T1S3 Mo2 T1S3DK2 BPM+FT-DK 2010 60/30 left, up A Dump, SIS100 India Inkind
BPM T1S3DX2 / / A Dump, SIS100
SEM-Grid T1S3DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 up A Dump, SIS100
13 T1S4 Mo1 T1S4DK1 BPM+FT-DK 2010 60/40 left, up A SIS100 India Inkind
BPM T1S4DX1 / / A SIS100
SEM-Grid T1S4DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 up A SIS100
14 T1S4 Mo2 T1S4DK2 FT-DK 2020 40/30 left, up A SIS100 India Inkind
SCR T1S4DF2 FT-DL 2210 ø100 mm FT-DF 2010 up A SIS100
15 T1S4 Mo3 T1S4DK3 BPM+FT-DK 2010 70/30 left, up A SIS100 India Inkind
BPM T1S4DX2 / / A SIS100
SEM-Grid T1S4DG3 FT-DL 2130 64x64x1,8 FT-DG 2040 up A SIS100
IPM T1S4DF3G / Detector: down and right PL: up A SIS100 aus T1S4DK4
16 T1S4 Mo4 T1S4DK4 BPM+FT-DK 2136+BIF 50/40 up A SIS100 FAIR-Beschaffung
BPM T1S4DX3 / / A SIS100
SEM-Grid T1S4DG4 FT-DL 2140 64x64x1,8 FT-DG FT-DG 2050 up A SIS100
IPM T1S4DF4G / Detector: down and right PL: up A SIS100
17 T8DU Mo1 T8DUDK1 BPM+FT-DK 2010+BIF 100/50 left, up A Dump India Inkind Achtung: Dump-Grube, früher Einbau
BPM T8DUDX1 / / A Dump
SEM-Grid T8DUDG1 FT-DL 2130 64x64x1,8 FT-DG 2040 left A Dump Änderung Einbaurichtung wegen DMU 19-11-18
IPM T8DUDF1G / Detector: up and right PL: left A Dump
18 TSX1 Mo1 TSX1DK1 FT-DK 2040 50/30 right, up A APPA, SFRS India Inkind
MWPC TSX1DG1G FT-DL 2030 ø100 mm FT-DG 2120 up A APPA, SFRS
SEM-Grid TSX1DG1 FT-DL 2110 64x64x1,2 FT-DG 2000 right A APPA, SFRS
19 TSX1 Mo2 TSX1DK2 BPM+FT-DK 2020 30/30 right, up A APPA, SFRS India Inkind
BPM TSX1DX1 / / A APPA, SFRS
SCR TSX1DF2 FT-DL 2210 ø100 mm FT-DF 2010 up A APPA, SFRS
20 TSX1 Mo3 TSX1DK3 FT-DK 2040 30/40 right, up A APPA, SFRS India Inkind
MWPC TSX1DG3G FT-DL 2030 ø100 mm FT-DG 2120 up A APPA, SFRS
SEM-Grid TSX1DG3 FT-DL 2110 64x64x1,2 FT-DG 2000 up A APPA, SFRS
21 TSX1 Mo4 TSX1DK4 FT-DK 2030+BIF 50/40 right, up A APPA, SFRS India Inkind
MWPC TSX1DG4G FT-DL 2030 ø100 mm FT-DG 2110 up A APPA, SFRS
SEM-Grid TSX1DG4 FT-DL 2130 64x64x1,8 FT-DG 2040 right A APPA, SFRS
IPM TSX1DF1G / Detector: right and down PL: up A APPA, SFRS
22 TSX1 Mo5 TSX1DK5 BPM+FT-DK 2060 40/30 right, up A APPA, SFRS India Inkind
BPM TSX1DX2 / / A APPA, SFRS
MWPC TSX1DG5G FT-DL 2030 ø100 mm FT-DG 2120 up A APPA, SFRS
SEM-Grid TSX1DG5 FT-DL 2110 64x64x1,2 FT-DG 2000 right A APPA, SFRS
PDC TSX1DI5 FT-DL 2050 ø100 mm FT-DI 2010 up A APPA, SFRS
23 TSF1 Mo1 TSF1DK1 BPM+FT-DK 2050 80/20 right, up A SFRS India Inkind
BPM TSF1DX1 / / A SFRS
MWPC TSF1DG1G FT-DL 2030 ø100 mm FT-DG 2110 up A SFRS
PDC TSF1DI FT-DL 2050 ø100 mm FT-DI 2010 up A SFRS
24 TSF1 Mo2 TSF1DK2 FT-DK 2010 80/20 right, up A SFRS India Inkind
SEM-Grid TSF1DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 right A SFRS
T1F2 no diagnostics
25 TFF1 Mo1 TFF1DK1 BPM+FT-DK 2050+BIF 40/50 left, up A SFRS India Inkind
BPM TFF1DX1 / A SFRS
MWPC TFF1DG1G FT-DL 2030 ø100 mm FT-DG 2110 up A SFRS
PDC TFF1DI1 FT-DL 2050 ø100 mm FT-DI 2010 up A SFRS
SEM-Grid TFF1DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 left A SFRS
IPM TFF1DF1G / Detector: left and down, PL: up A SFRS
26 TSX2 Mo1 TSX2DK1 FT-DK 2080 ohne linken Flansch 30/40 right, up B APPA India Inkind
SCR TSX2DF1 FT-DL 2210 ø100 mm FT-DF 2010 up B APPA
27 TXL1 Mo1 TXL1DK1 FT-DK 2080 ohne linken Flansch 45/30 right, up B India Inkind
SCR TXL1DF1 FT-DL 2210 ø100 mm FT-DF 2010 up B
28 TXL2 Mo1 TXL2DK1 FT-DK 2030 50/30 right, up B APPA India Inkind
SEM-Grid TXL2DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 right B APPA
MWPC TXL2DG1G FT-DL 2030 ø100 mm FT-DG 2110 up B APPA
29 TXL2 Mo2 TXL2DK2 FT-DK 2010 20/30 right, up B APPA India Inkind
SCR TXL2DF2 FT-DL 2230 ø120 mm FT-DF 2020 up B APPA
30 TXL2 Mo3 TXL2DK3 BPM+FT-DK 2030+BIF 50/30 right, up B APPA India Inkind
BPM TXL2DX1 / / B APPA
SEM-Grid TXL2DG3 FT-DL 2130 64x64x1,8 FT-DG 2040 right B APPA
MWPC TXL2DG3G FT-DL 2030 ø100 mm FT-DG 2110 up B APPA
IPM TXL2DF3G / PL:right B APPA
31 TXL2 Mo4 TXL2DK4 FT-DK 2134+BPM 50/30 right, up B APPA FAIR-Beschaffung (with integrated BPM)
SCR TXL2DF4 FT-DL 2230 ø120mm FT-DF 2020 up B APPA
BPM TXL2DX2 B APPA
32 TXL2 Mo5 TXL2DK5 FT-DK 2050 50/30 right, up B APPA India Inkind
MWPC TXL2DG5G FT-DL 2030 ø100 mm FT-DG 2110 up B APPA
SEM-Grid TXL2DG5 FT-DL 2130 64x64x1,8 FT-DG 2040 up against beam direction B APPA
PDC TXL2DI5 FT-DL 2050 ø100 mm FT-DI 2010 right B APPA
33 TXL2 Mo6 TXL2DK6 BPM+FT-DK 2134+BIF 50/30 right, up B APPA FAIR-Beschaffung
SEM-Grid TXL2DG6 FT-DL 2130 64x64x1,8 FT-DG 2040 up B APPA
MWPC TXL2DG6G FT-DL 2030 ø100 mm FT-DG 2110 right B APPA
BPM TXL2DX3 B APPA
IPM TXL2DF6G / B APPA kein Einbauraum
34 TXL3 Mo1 TXL3DK1 FT-DK 2030 60/30 right, up B APPA India Inkind
SEM-Grid TXL3DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 right B APPA
MWPC TXL3DG1G FT-DL 2030 ø100 mm FT-DG 2110 up B APPA
35 TXL3 Mo2 TXL3DK2 BPM+FT-DK 2030+BIF 60/30 right, up B APPA India Inkind
BPM TXL3DX1 B APPA
SEM-Grid TXL3DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 right B APPA
MWPC TXL3DG2G FT-DL 2030 ø100 mm FT-DG 2110 up B APPA
IPM TXL3DF2G / Detector: left and down, PL: up B APPA
36 TXL3 Mo3 TXL3DK3 FT-DK 2010 60/30 right, up B APPA India Inkind
PDC TXL3DI3 FT-DL 2050 ø100 mm FT-DI 2010 right B APPA
37 T1X1 Mo1 T1X1DK1 FT-DK 2133 50/40 right / left A FAIR-Beschaffung
BPM T1X1DX1 / A
SEM-Grid T1X1DG1 FT-DL 2120 64x64x1,2 FT-DG 2010 right A
MWPC T1X1DG1G FT-DL 2030 ø100 mm FT-DG 2120 left A
SCR T1X1DF1 FT-DL 2220 ø100 mm FT-DF 2011 left A
PDC T1X1DI1 right A moved to DK3
IPM T1X1DF1G / Detector: left and up, PL: right A
38 T1X1 Mo2 T1X1DK2 BPM+ FT-DK 2010 50/40 right A India Inkind
BPM T1X1DX2 / A
SEM-Grid T1X1DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 right A
39 T1X1 Mo3 T1X1DK3 FT-DK 2130 50/40 right A India Inkind
MWPC T1X1DG3G FT-DL 2030 ø100 mm FT-DG 2110 right A
PDC T1X1DI3 FT-DL 2050 ø100 mm right A
40 T1X1 Mo4 T1X1DK4 FT-DK 2130 50/40 right A India Inkind
MWPC T1X1DG3G FT-DL 2030 ø100 mm FT-DG 2110 right A
SEM-Grid T1X1DG3 FT-DL 2130 64x64x1,8 FT-DI 2020 right, against beam direction A
41 T1X2 Mo1 T1X2DK1 FT-DK 2131 60/20 right B India Inkind Achtung: Schräge Ebene (C. Englert)
BPM T1X2DX1 / B
SEM-Grid T1X2DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 right B
MWPC T1X2DG1G FT-DL 2030 ø100 mm FT-DG 2110 right B
42 T1X2 Mo2 T1X2DK2 FT-DK 2130 60/20 right B India Inkind Achtung: Gestell G004 (C. Englert)
SEM-Grid T1X2DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 right B
MWPC T1X2DG2G FT-DL 2030 ø100 mm FT-DG 2110 right B
43 T1X2 Mo3 T1X2DK3 FT-DK 2132 40/50 left B India Inkind
BPM T1X2DX2 / B
SEM-Grid T1X2DG3 FT-DL 2130 64x64x1,8 FT-DG 2040 left B
MWPC T1X2DG3G FT-DL 2030 ø100 mm FT-DG 2110 left B
PDC T1X2DI3 FT-DL 2050 ø100 mm FT-DI 2010 left B
IPM T1X2DF3G / Detector: right and up, PL: left B
44 T1F1 Mo1 T1F1DK1 FT-DK 2132 60/30 left B India Inkind
BPM T1F1DX1 / left B
SEM-Grid T1F1DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 left B
MWPC T1F1DG1G FT-DL 2030 ø100 mm FT-DG 2110 left B
PDC T1F1DI1 FT-DL 2050 ø100 mm FT-DI 2010 left B
45 T1C1 Mo1 T1C1DK1 FT-DK 2020 40/30 left A India Inkind Achtung: Schräge Ebene (C. Englert)
SCR T1C1DF1 FT-DL 2210 ø100 mm FT-DF 2010 left A
46 T1C1 Mo2 T1C1DK2 FT-DK 2135 50/20 left A FAIR Beschaffung Achtung: Schräge Ebene (C. Englert)
BPM T1C1DX1 A
MWPC T1C1DG2G FT-DL 2030 ø100mm FT-DG 2110 left A
SEM-Grid T1C1DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 left, against beam direction A
47 T1C1 Mo3 T1C1DK3 FT-DK 2135 60/30 left, right A FAIR-Beschaffung Achtung: Gestell G004 (C. Englert)
MWPC T1C1DG3G FT-DL 2030 ø100 mm FT-DG 2110 left A
SEM-Grid T1C1DG3 FT-DL 2130 64x64x1,8 FT-DG 2040 left, against beam direction A
PDC T1C1DI3 FT-DL 2050 ø100 mm FT-DI 2010 right A
48 T1C2 Mo1 T1C2DK1 FT-DK 2020 40/30 left A India Inkind Achtung: Gestell G004 (C. Englert)
MWPC T1C2DG1G FT-DL 2030 ø100 mm FT-DG 2120 left A
49 T1C2 Mo2 T1C2DK2 FT-DK 2137 50/20 left A FAIR-Beschaffung
MWPC T1C2DG2G FT-DL 2030 ø100 mm FT-DG 2120 left A
PDC T1C2DI2 FT-DL 2050 ø100 mm FT-DI 2010 left A
50 T1D1 Mo1 T1D1DK1 FT-DK 2020 50/40 right A India Inkind Achtung: Gestell G004 (C. Englert)
SCR T1D1DF1 FT-DL 2210 ø100 mm FT-DF 2010 right A
51 T1D1 Mo2 T1D1DK2 FT-DK 2138 90/80 right A FAIR-Beschaffung
BPM T1D1DX1 A
SEM-Grid T1D1DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 right A
MWPC T1D1DG2G FT-DL 2030 ø100 mm FT-DG 2110 right A
PDC T1D1DI2 FT-DL 2050 ø100 mm FT-DI 2010 right A
IPM T1D1DF2G Detector: left and up, PL: right A
52 TPP1 Mo1 TPP1DK1 BPM+FT-DK 2030 80/30 left, up B India Inkind
BPM TPP1DX1 B
SEM-Grid TPP1DG1 FT-DL 2130 64x64x1,8 FT-DG 2040 left B
MWPC TPP1DG1G FT-DL 2030 ø100 mm FT-DG 2110 up B
53 TPP1 Mo2 TPP1DK2 BPM+FT-DK 2050 80/30 left, up B India Inkind
BPM TPP1DX2 B
SEM-Grid TPP1DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 left B
MWPC TPP1DG2G FT-DL 2030 ø100 mm FT-DG 2110 up B
PDC THP1DI2 FT-DL 2050 ø100 mm FT-DI 2010 up B
54 TPP2 Mo1 TPP2DK1 BPM+FT-DK 2080+BIF ohne linken Flalge 40/40 right, up B India Inkind
BPM TPP2DX1 B
SEM-Grid TPP2DG1 FT-DL 2110 64x64x1,2 FT-DG 2000 up B
IPM TPP2DF1G B
55 TPP2 Mo2 TPP2DK2 BPM+FT-DK 2020+BIF 40/40 B India Inkind
BPM TPP2DX2 B eliminated
SEM-Grid TPP2DG2 FT-DL 2110 64x64x1,2 FT-DG 2000 up B
IPM TPP2DF2G B eliminated
56 TPP2 Mo3 TPP2DK3 FT-DK 2020 40/40 B India Inkind
SEM-Grid TPP2DG3 FT-DL 2110 64x64x1,2 FT-DG 2000 up B
BPM TPP2DX2 B
IPM TPP2DF2G B
57 TAP1 Mo1 TAP1DK1 BPM+FT-DK 2020 20/25 left, up C India Inkind
BPM TAP1DX1 C
SEM-Grid TAP1DG1 FT-DL 2110 64x64x1,2 FT-DG 2000 up C
58 TAP2 Mo1 TAP2DK1 FT-DK 2020 60/40 right, up C India Inkind
SEM-Grid TAP2DG1 FT-DL 2110 64x64x1,2 FT-DG 2000 up C
59 TAP2 Mo2 TAP2DK2 BPM+FT-DK 2010+BIF 60/40 right, up C India Inkind
BPM TAP2DX1 C
SEM-Grid TAP2DG2 FT-DL 2130 64x64x1,8 FT-DG 2040 up C
IPM TAP2DF2G C
60 TFC1 Mo1 TFC1DK1 BINP chamber 85/170 left, up C geplante FAIR-Beschaffung: BINP TCR1 (CF400)
BPM TFC1DX1 ø400×200 mm BINP TCR1 type C
SCR TFC1DF1 ø400×200 mm BINP TCR1 type up C
61 FREX Mo1 FRFDK1 BINP chamber 380/170 left, up C geplante FAIR-Beschaffung: BINP TCR1 (CF400)
BPM FRFDX1 ø400×200 mm BINP TCR1 type C
SCR FRFDF1 ø400×200 mm BINP TCR1 type up C
TRR1 no diagnostics
62 THS1/THE1 Mo1 THE1DK1 BPM+FT-DK 2020 40/30 up C India Inkind
BPM THE1DX1 C
SEM-Grid THE1DG1 FT-DL 2110 64x64x1,2 FT-DG 2000 up C ersetzen durch SCR
63 THS1/THE1 Mo2 THE1DK2 FT-DK 2020 30/30 right, up C India Inkind
SCR THE1DF2 FT-DL 2210 ø100 mm FT-DF 2010 up C
64 THS1/THE1 Mo3 THE1DK3 BPM+FT-DK 2020 40/30 right, up C India Inkind
SEM-Grid THE1DG3 FT-DL 2110 64x64x1,2 FT-DG 2000 up C ersetzen durch SCR
65 THS1/THE1 Mo4 THE1DK4 BPM+FT-DK 2020 20/30 right, up C India Inkind
BPM THE1DX2 C
SCR THE1DF4 FT-DL 2210 ø100 mm FT-DF 2010 up C
66 THS1/THE1 Mo5 THE1DK5 BPM+FT-DK 2020 40/30 right, up C India Inkind
SCR THE1DF5 FT-DL 2210 ø100 mm FT-DF 2010 up C
67 THS1/THE1 Mo6 THE1DK6 BPM+FT-DK 2010 90/10 up C India Inkind
BPM THE1DX3 C in AtB9.7 später vor QS17
SEM-Grid THE1DG6 FT-DL 2130 64x64x1,8 FT-DG 2040 up C ersetzen durch SCR
68 THS1/THE1 Mo7 THE1DK7 BPM+FT-DK 2010 60/10 up C India Inkind
BPM THE1DX4 C
SEM-Grid THE1DG7 FT-DL 2130 64x64x1,8 FT-DG 2040 up C ersetzen durch SCR
69 TNC1 Mo1 TNC1DK1 FT-DK 2030 80/50 C India Inkind
MWPC TNC1DG1G FT-DL 2030 ø100 mm FT-DG 2110 up C
PDC TNC1DI1 FT-DL 2050 FT-DI 2010 right C
70 TNC1 Mo2 TNC1DK2 special required 140/100 C geplante FAIR-Beschaffung:new design required at this position, Entry and Exit Flanges 2xCF200, Flange for vacuum pump: 1xCF150, Flange for vacuum measurements: 2xCF40 Flange for detector: CF250
SCR TNC1DF2 C
71 TNC1 Mo3 TNC1DK3 FT-DK 2050 C
MWPC TNC1DG3G FT-DL 2030 ø100 mm FT-DG 2110 up C
PDC TNC1DI3 FT-DL 2050 ø100 mm FT-DI 2010 right C
72 TNC1 Mo4 / HADES TNC1DK4 FT-DK 2030 C XCBMDK1 ???
SCR TNC1DF4 FT-DL 2230 ø120 mm FT-DF 2020 up C
73 TNC1 Mo5 / CBM TNC1DK5 FT-DK 2030 C XCBMDK2 ???
SCR TNC1DF5 FT-DL 2230 ø120 mm FT-DF 2020 up C
74 TSN1 Mo1 TSN1DK1 FT-DK 2020 C
SCR TSN1DF1 FT-DL 2210 ø100 mm FT-DF 2010 up C
75 TSN1 Mo2 TSN1DK2 FT-DK 2020 C
SEM-Grid TSN1DG2 FT-DL 2110 64x64x1,2 FT-DG 2000 up C
76 TSN1 Mo3 TSN1DK3 FT-DK 2020 C
SCR TSN1DF3 FT-DL 2210 ø100 mm FT-DF 2010 up C
77 TSR1 Mo1 TSR1DK1 FT-DK 2020 C
SEM-Grid TSR1DG1 FT-DL 2110 64x64x1,2 FT-DG 2000 up C
78 XAP1 Mo1 XAP1DK1 FT-DK 2050 B APPA
MWPC XAP1DG1G FT-DL 2030 ø100 mm FT-DG 2110 tof front B APPA
PDC XAP1DI1I FT-DL 2050 ø100 mm FT-DI 2010 top back B APPA
SCR XAP1DF1 FT-DL 2230 ø120 mm FT-DF 2020 right B APPA
SEM-Grid XAP1DG1G FT-DL 2130 64x64x1,8 FT-DG 2040 left B APPA
79 XAPD Mo1 XAPDDK1 FT-DK 2030 B APPA
MWPC XAPDDG1G FT-DL 2030 ø100 mm FT-DG 2110 tof front B APPA
SCR XAPDDF1 FT-DL 2230 ø120 mm FT-DF 2020 right/left B APPA
80 XBM1 Mo1 XBM1DK1 FT-DK 2060 B APPA left port blocked by dipole!
MWPC XBM1DG1G FT-DL 2030 ø100 mm FT-DG 2110 tof front B APPA
SCR XBM1DF1 FT-DL 2210 ø100 mm FT-DF 2010 top back B APPA
PDC XBM1DI1I FT-DL 2050 ø100 mm FT-DI 2010 right B APPA
81 XBM1 Mo2 XBM1DK2 FT-DK 2050 B APPA
MWPC XBM1DG2G FT-DL 2030 ø100 mm FT-DG 2110 tof front B APPA
SCR XBM1DF2 FT-DL 2230 ø120 mm FT-DF 2020 right B APPA
PDC XBM1DI2I FT-DL 2050 ø100 mm FT-DI 2010 top back B APPA
SEM-Grid XBM1DG2G FT-DL 2130 64x64x1,8 FT-DG 2040 left B APPA
82 XPP2 Mo1 XPP2DK1 FT-DK 2020 B APPA
SCR XPP2DF1 FT-DL 2210 ø100 mm FT-DF 2010 top B APPA
SEM-Grid XPP2DG1 FT-DL 2110 64x64x1,2 FT-DG 2000 left/right B APPA
83 XPP2 Mo2 XPP2DK2 FT-DK 2020 B APPA
SCR XPP2DF2 FT-DL 2210 ø100 mm FT-DF 2010 top B APPA
SEM-Grid XPP2DG2 FT-DL 2110 64x64x1,2 FT-DG 2000 left/right B APPA
playground/playground/test_table.txt · Last modified: 2021/02/03 20:17 by andreasreiter