Detector Hardware

The scintillating screen is inserted into the beam under an angle of 45°. Through a viewport, located at 90° with respect to the beam, a camera observes the screen.

The drawing of the scintillating screen setup on a flange with a target under 45° in respect to the beam.

The mechanical constituents of one Scintillating Screen Setup are the following parts:

  • Detector consisting of scintillating screen and target holder.
  • Pneumatic driven linear actuator.
  • Diagnostic chamber for installation of linear actuators.
  • Additional parts for detector installation on linear actuator.

Pneumatic Driven Linear Actuator

The linear actuator moves the detector (scintillating screen and holder) into the beam center and out of the beam. The four different detectors are foreseen correspond to four different linear actuators.

Detector Distance Flange-Beam Center [mm] Stroke [mm] Bakeout BD-type number Drawing number
FT-DF 2010 270 150 No FT-DL 2210 BD-1018821-A-000
FT-DF 2011 270 150 Yes FT-DL 2220 BD-1018881-A-000
FT-DF 2020 370 200 No FT-DL 2230 BD-1014852-A-000
FT-DF 2021 370 200 Yes FT-DL 2240 BD-1018450-A-000

Technical drawing of linear actuator with camera setup.

Optical Setup

The optical constituents of one Scintillating Screen are the following parts:

Screen material

The detector consists of the scintillating screen (target) and the target holder. The scintillating screen is a round disk of scintillating material (solid or coated material), fixed in a holder with permanent alignment marks outside the active area.

The technical drawing (left) and photo (right) of the scintillating screen on target holder.

SCR Material Type Application
Al2O3:Cr (Chromox) Solid target material Standard light applications
Gd2O2S:Tb (P43) Coated on a plate Low light applications
YAG:Ce Solid target material Low light applications

In the HEBT lines, two different detector sizes are used with an active area of Ø 100 mm and Ø 120 mm, mainly Chromox.

Detector size (active area) Bake-out BD-type number Drawing number
D100 No FT-DF 2010 BD-1018552-A-000
instrument_hardware.1544101757.txt.gz · Last modified: 2018/12/06 14:09 by vschaefer