This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
hi:hi:gsioldavd [2019/09/20 16:35] p.boutachkov created |
hi:hi:gsioldavd [2021/03/05 12:32] (current) reeg |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== Measured Voltages | ====== Measured Voltages | ||
- | The measurement is performed at 500 V with a GE13121, 2kV probe | + | Measured with Caen DT1470ET |
- | The pins are counted clockwise facing the socket, staring from the pin next to the lock | + | |
+ | ^ V[V] ^ I[uA] ^ | ||
+ | | 100 | 63 | | ||
+ | | 400 | 265 | | ||
+ | | 500 | 332 | | ||
+ | | 600 | 399 | | ||
+ | | 700 | 466 | | ||
+ | | 800 | 534 | | ||
+ | | 900 | 601 | | ||
+ | | 1000 | 669 | | ||
+ | | 1100 | 736 | | ||
+ | | 1200 | 804 | | ||
+ | | 1300 | 871 | | ||
+ | | 1400 | 939 | | ||
+ | | 1500 | 1007 | | ||
+ | | 1600 | 1074 | | ||
+ | | 1700 | 1142 | | ||
+ | | 1800 | 1209 | | ||
+ | | 1900 | 1277 | | ||
+ | |||
+ | The measurement is performed at **500 V** with a GE13121, 2kV probe and Micsig battery operated TO1152 150 MHz oscilloscope. | ||
+ | The pins are counted clockwise facing the socket, staring from the pin next to the lock | ||
^ Pin ^ Connection ^ V[V] ^ | ^ Pin ^ Connection ^ V[V] ^ | ||
- | | 1 | D1 | | | + | | 1 | D1 | 358 | |
- | | 2 | D1 | | | + | | 2 | K | 446 | |
- | | 1 | D1 | | | + | | 3 | D2 | 322 | |
- | | 1 | D1 | | | + | | 4 | D4 | 242 | |
- | | 1 | D1 | | | + | | 5 | D6 | 194 | |
- | | 1 | D1 | | | + | | 6 | D8 | 134 | |
- | | 1 | D1 | | | + | | 7 | D10 | 54 | |
- | | 1 | D1 | | | + | | 8 | A | 2 | |
+ | | 9 | out | 2 | | ||
+ | | 10 | D9 | 110 | | ||
+ | | 11 | D7 | 170 | | ||
+ | | 12 | D5 | 216 | | ||
+ | | 13 | D3 | 276 | | ||
+ | | 14 | out | 2 | |