====== T-Test7811 ======
These three T-adapters are optional and only fit into the testing crate. For use the NI-cable to the PXI7811-board carrying the signals to be examined has to be disconnected at the MAPS-adapter and must be feed to one arm of a T-adapter. Then an additional cable is introduced at the other arm of T-adapter and feed to the origional port at the MAPS-adapter to close the signal line again. Having done that an examination of signals can be executed at VG-pins on the back of the test-crate or with an VG-extender board at the fron side.\\
^ ^ ^
|{{ :projects:maps:fehlermessadapter_maps.jpg?direct&300 |T-Tests internal}} |Signals to be measured and pins to measure on:\\ {{:projects:maps:belegung_vhdci_maps-bus_test.jpg?direct&300|Signals to test}} |
Use of T-Testadapter: There are two different sources with two different cables running to the NI PXI-7811R FPGA-board. In order to examine signal flow fit in T-Testadapter by disconnecting direct connection (upper cable) at the MAPS-adapter in built in the "T" and an additional cable (like lower combination):
^ Device ^ Cable ^ Device ^
| **MAPS-Adapter** | SHC68-68-RDIO | **PXI-7811R** \\ FBGA board |
| connector (at cable) \\ 68-pin 0.050 D-Type | {{ :projects:maps:t-adapternutzung.jpg?nolink&400 |T-Adapternutzung}} | connector 2/3 (at cable) \\ VHDCI 68-pin male |
| | SH68-68-EP ############## SHC68-68-RDIO | |
| **MAPS-Interface** \\ (Fa. Hörmann-IMG ) | SHC68-C68-S | **PXI-7811R** \\ FBGA board |
| connector (at cable) \\ VHDCI 68-pin male | {{ :projects:maps:t-adapternutzung_zur_img-kiste.jpg?nolink&400 |}} | connector 0/1 (at cable) \\ VHDCI 68-pin male |
| | SHC68-68-RDIO ############## SHC68-68-RDIO | |