☚ [[projects:maps:overview|Back]] ★
====== National Instruments Equipment used in this project: ======
===== NI-Crate and Components =====
This system is designed to have two crates if extended to full 128 AC-Trafo capacity.
2 * PXI-Crates "PXI-1045" (currently only 1):
(order number 778645-01)\\
[[http://www.ni.com/pdf/products/us/pxi1045.pdf]]
2 * PXI-Controllers "PXI-8110" (currently only one):\\
[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/206809]]
Warum kein realtime controller PXI-8110RT ?
16 * PXI-ADC board "PXI6133" (currently 9):\\
[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/201937]]
2 * PXI-FGA board "PXI7811R" (currently 1):
===== cables =====
__**(A)** 16 * cables type "SH68-68-EP" for connecting **PXI-6133 to MAPS-Adapter:**__\\
(order number 184749-01 (1m) )\\
2x blauer 68-pin 0.050 D-Type --- 68-pin 0.050 D-Type **√**\\
[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/11799]]\\
wire mapping (interner Aufbau)->\\
[[http://digital.natinst.com/public.nsf/$CXIV/ATTACH-AEEE-883STQ/$FILE/SH68-68-EP.png]]
__**(B)** 4x cables "SHC68-68-RDIO" for connecting **PXI-7811R (Con2/Con3) to MAPS-Adapter:**__\\
(order number 191667-01 (1m) )\\
blauer 68-pin 0.050 --- silber VHDCI 68-pin male**√** \\
This cable can be used for conneting to SCB68 or a chassis cRIO-9151 for field IOs. It has 40 DIO lines each twisted with an DGND line (40). Therefore some of the DGND have to chair the same pins at only 68 pole conectors on both ends. It' s better sweeted with use of PXI-7811R.\\
[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/203198]]\\
wire mapping (interner Aufbau)->\\
[[http://digital.natinst.com/public.nsf/$CXIV/ATTACH-AEEE-883R8C/$FILE/SHC68-68-RDIO.png]]
__**(C)** 4x cables "SHC68-C68-S" for connecting **PXI-7811R (Con0/Con1) to MAPS-Interface:**__\\
(order number 186380C-0R5)\\
silber VHDCI 68-pin male --- silber VHDCI 68-pin male **√**\\
[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/206792]]\\
wire mapping (interner Aufbau)->\\
[[http://digital.natinst.com/public.nsf/$CXIV/ATTACH-AEEE-883QMB/$FILE/SHC68-68.png]]
===== Alternative cable ======
(currently used, 2 p.):\\
__**(B1)** 4x cables "SH68-C68-S" for connecting **PXI-7811R to MAPS-Adapter:**__\\
(order number 186381C-02 (2m))\\
blauer 68-pin 0.050 --- silber VHDCI 68-pin male**√**\\
This cable is designed origionally for use with in and out goimg analog signals. Used with PXI-7811R there will be DIO lines twisted together pair wise that should not be handle this way.\\
[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/206793]]\\
wire mapping (interner Aufbau)->\\
[[http://digital.ni.com/public.nsf/$CXIV/ATTACH-AEEE-8DBNQQ/$FILE/SH68-C68-S.PNG]]
===== cable that should not be used =====
This cable is to use together with counting device:\\
__16x cable "SH68-68-D1" order number 183432 for counter boards:__\\
blauer 68-pin 0.050 D-Type --- 68-pin 0.050 D-Type\\
[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/11801]]\\
wire mapping (interner Aufbau)->\\
[[http://digital.natinst.com/public.nsf/$CXIV/ATTACH-AEEE-883TMB/$FILE/SH6868-D1.png]]
----
☚ [[projects:maps:overview|Back]] ★