This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
ds:hardware:mtca:overview [2018/02/26 08:13] tobiashoffmann [µTCA Controllers] |
ds:hardware:mtca:overview [2024/09/04 15:18] (current) tobiashoffmann [µTCA Crates] |
||
---|---|---|---|
Line 5: | Line 5: | ||
Envisaged are DAQ systems for fast sampling ADCS eg BPM systems, scaler systems for higher sampling rates and video imaging systems. | Envisaged are DAQ systems for fast sampling ADCS eg BPM systems, scaler systems for higher sampling rates and video imaging systems. | ||
- | So far BI has tested following µTCA parts: | + | |
===== µTCA Crates ===== | ===== µTCA Crates ===== | ||
- | * ELMA MTCA.4 6-Slot | + | * ELMA MTCA.4 6-Slot |
- | * Schroff MTCA.4 6 Slot | + | * Schroff MTCA.4 6 Slot (vertical) |
- | * Vadatech VT811 | + | * Vadatech VT811 12-slot |
* N.A.T. Native R2 6-Slot MTCA.4 2HE | * N.A.T. Native R2 6-Slot MTCA.4 2HE | ||
* N.A.T. Native R9 12-Slot MTCA.4 9HE | * N.A.T. Native R9 12-Slot MTCA.4 9HE | ||
+ | * Powerbridge RackPak/ | ||
Line 21: | Line 22: | ||
* ADlink AMC-1000 | * ADlink AMC-1000 | ||
* [[: | * [[: | ||
- | * [[: | + | * [[:am902|Concurrent AM902/ |
+ | * [[ds: | ||
===== µTCA MCHs ===== | ===== µTCA MCHs ===== | ||
- | * div. NAT MCH (6 Slot, 12 Slot Phys) | + | * [[: |
* Vadatech UTC002 | * Vadatech UTC002 | ||
+ | |||
===== µTCA Modules ===== | ===== µTCA Modules ===== | ||
- | * SIS8300 10 Ch. ADC with RT | + | * SIS8300 10 Ch. ADC with RTM |
* AM4301 4 Port NIC | * AM4301 4 Port NIC | ||
* TAMC260 1 Slot PMC-Carrier for AMC | * TAMC260 1 Slot PMC-Carrier for AMC | ||
- | * Dual HPC FMC Carrier board MTCA.4 | + | * Dual HPC FMC Carrier board MTCA.4 |
- | * FMC ADC 250MHz 16 Bit | + | * FMC ADC 250MHz 16 Bit (open hardware) |
+ | * FMC ADC 105MHz 14 BIt (open hardware) | ||
* SIS8300KU 10.Ch. ADC with RTM | * SIS8300KU 10.Ch. ADC with RTM | ||
* SIS8800 32 Ch. Scaler | * SIS8800 32 Ch. Scaler | ||
* SIS8980 16 Ch LE Discriminator RTM | * SIS8980 16 Ch LE Discriminator RTM | ||
- | * Vadatech AMC217 8-Ch Switch | + | * [[ds: |
+ | * [[: | ||
+ | * TAMC532 - 32Ch ADC 14 Bit with RTM | ||
+ | * FAIR Timing Receiver Node FTRN-AMC | ||
+ | * IOXOS IFC-1410 FMC Carrier & ADC-3117 FMC | ||
+ | |||
+ | ===== Setup MTCA.4 System ===== | ||
+ | |||
+ | The main standard MTCA-4 system consists of: | ||
+ | * [[ds: | ||
+ | * [[fair-bd: | ||
+ | * NAT-PM-AC600D | ||
+ | * RackPak/ | ||
+ | |||
+ | |||
+ | ===== µTCA IPMI Control ===== | ||
+ | |||
+ | Get M State via sensor: | ||
+ | Example: Handle pulled out = M1 - board gets only management power | ||
+ | $ ipmitool -I lan -H < | ||
+ | Locating sensor record...\\ | ||
+ | Sensor ID : HS 009 AMC5 (0x3c)\\ | ||
+ | Entity ID : 193.101\\ | ||
+ | Sensor Type (Discrete): PICMG FRU Hotswap\\ | ||
+ | States Asserted | ||
+ | [Transition to M1]\\ | ||
+ | |||
+ | Example 2: Handle pushed in (M4) - board is on | ||
+ | |||
+ | $ ipmitool -I lan -H < | ||
+ | Locating sensor record...\\ | ||
+ | Sensor ID : HS 009 AMC5 (0x3c)\\ | ||
+ | | ||
+ | | ||
+ | | ||
+ | [Transition to M4]\\ | ||
+ | |||
+ | Switch of dedicated FRU: | ||
+ | $ ipmitool -I lan -H < | ||
+ | |||
+ | Switch it on: | ||
+ | $ ipmitool -I lan -H < | ||
+ | |||
+ | Cold reboot of complete system: | ||
+ | $ ipmitool -I lan -H < | ||
+ | |||
+ | Warm-reboot: | ||
+ | $ ipmitool -I lan -H < | ||
+ | |||