User Tools

Site Tools


projects:bif-monitor:application

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
projects:bif-monitor:application [2011/02/09 13:01]
dorn [Linear Feedthrouh UNI-DL 1140]
projects:bif-monitor:application [2011/08/24 13:57]
candre
Line 1: Line 1:
 ====== Current Application - BIF-Monitor @ UNILAC ====== ====== Current Application - BIF-Monitor @ UNILAC ======
  
-During the last years the BIF method was applied successfully at the GSI heavy ion LINAC for various ion species and energies between and 11.4 MeV/u. In 2009 four x-y BIF-Monitors with eight intensified camera systems in total will be installed at the UNILAC. Two cameras per BIF-station record beam profiles in horizontal and vertical direction (x,y):\\ +During the last years the BIF method was applied successfully at the GSI heavy ion LINAC for various ion species and energies between 1.4 and 11.4 MeV/u. 
-{{:projects:bif-monitor:ut_hor_ver_aufbau_80dpi.png|}}\\ +
-''X-Y orientated intensified cameras at UNILAC UT-1 station''+
  
-{{:projects:bif-monitor:x2-aufbau_72dpi.jpg|}}\\ +For non-intercepting beam profile measurements at UNILAC high current operation, four BIF monitors were istalled. Two cameras per BIF-station record beam profiles in horizontal and vertical direction (x,y):\\ 
-''BIF-Monitor with a motorized filter wheel and 10 nm narrowband interference filters for spectral investigation of nitrogen emissions at the UNILAC experimental cave X2''+\\ 
 +{{:projects:bif-monitor:bif_setup_new_small.png|}} \\ 
 +**BIF setup at UNILAC: Intensified cameras in horizontal & vertical direction** 
 +\\ 
 +\\
  
-===== Technical Drawings ===== +====== BIF setup locations ======
-==== Diagnostic Box UNI-DK 1130 ==== +
-{{:projects:bif-monitor:kammer_bif.jpg|}}+
  
-{{:projects:bif-monitor:std-000-l33.010.000_diagnosekammer.pdf|}}+{{:projects:bif-monitor:unilac_bif_new_3.png|}}  \\ 
 +**Four installed BIF monitors, two planned**     \\ 
 +\\
  
-{{:projects:bif-monitor:std-000-l33.010.000_diagnosekammer_stkl.pdf|}}+====== BIF spectral investigation ======
  
-==== Diagnostic Box UNI-DK 1131 ==== +{{:projects:bif-monitor:x2-aufbau_72dpi.jpg|}}\\ 
- +''BIF-Monitor with a motorized filter wheel and 10 nm narrowband interference filters for spectral investigation of nitrogen emissions at the UNILAC experimental cave X2''
-{{:projects:bif-monitor:uni-dk_1131.jpg|}} +
- +
-{{:projects:bif-monitor:std-000-l33.015.000_diagnosekammer_stkl.pdf|}} +
- +
-{{:projects:bif-monitor:std-000-l33.015.000_diagnosekammer_uni-dk_1131.pdf|}} +
- +
-==== Linear Feedthrouh UNI-DL 1140 ==== +
-This feedthrouh is used for positioning the calibration tool on beam axis +
- +
-{{:projects:bif-monitor:unidl1140.jpg|}}{{:projects:bif-monitor:unidl1140_2.jpg|}} +
- +
- +
-All drawings are available in GSI-Zeichnungsarchiv (ZT) +
-==== Calibration Tool ==== +
- +
-{{:projects:bif-monitor:bild1.jpg|}}{{:projects:bif-monitor:bild2.jpg|}} +
- +
-**Assemby Drawing STD-000-L33.031.000A Justiereinheit** +
- +
-{{:projects:bif-monitor:std-000-l33.031.000_a_justiereinheit.pdf|}} +
- +
-List of Parts STD-000-L33.031.000A Justiereinheit +
- +
-{{:projects:bif-monitor:std-000-l33.031.000_a_justiereinheit_stkl.pdf|}} +
- +
-**Subassembly** +
- +
-Bügel STD-000-L33.311.000A +
- +
-{{:projects:bif-monitor:std-000-l33.311.000a_buegel.pdf|}} +
- +
-{{:projects:bif-monitor:std-000-l33.311.000a_buegel_stkl.pdf|}} +
- +
-Bügel STD-000-L33.311.001 +
- +
-{{:projects:bif-monitor:std-000-l33.311.001a_buegel.pdf|}} +
- +
-Bolzen DG 010.010.010B +
- +
-{{:projects:bif-monitor:dg_010.010.010b_bolzen.pdf|}} +
- +
-Überwurfmutter DG 010.000.080 +
- +
-{{:projects:bif-monitor:dg_010.000.080_ueberwurfmutter.pdf|}} +
- +
-**Parts** +
- +
-Seitenteil 1 STD-000-L33.310.001A +
- +
-{{:projects:bif-monitor:std-000-l33.310.001a_seitenteil_1.pdf|}} +
- +
-Seitenteil 2 STD-000-L33.310.002A +
- +
-{{:projects:bif-monitor:std-000-l33.310.002a_seitenteil_2.pdf|}} +
- +
-LED-Halterung STD-000-L33.310.003 +
- +
-{{:projects:bif-monitor:std-000-l33.310.003_led-halterung.pdf|}} +
- +
-Isolierplatte STD-000-L33.310.004 +
- +
-{{:projects:bif-monitor:std-000-l33.310.004_isolierplatte.pdf|}} +
- +
- +
- +
- +
- +
- +
- +
-==== Assembly ==== +
- +
-**Linear Feedthrouh with Calibration Tool** +
-**UNI-DZ 1230** +
- +
-//STD-000-L33.000.000A// +
- +
-{{:projects:bif-monitor:uni-dz_1230.jpg|}} +
- +
-{{:projects:bif-monitor:std-000-l33.000.000a_lineardurchfuehrung_komplett_stkl.pdf|}} +
- +
-{{:projects:bif-monitor:std-000-l33.000.000a_lineardurchfuehrung_komplett.pdf|}} +
- +
- +
- +
- +
- +
- +
- +
- +
- +
-==== Camera Mounting and Covering ==== +
- +
-{{:projects:bif-monitor:kamerahalterung1.jpg|}} +
- +
-{{:projects:bif-monitor:std-000-l33.040.000_kamerahalterung.pdf|}}+
  
-{{:projects:bif-monitor:std-000-l33.040.000_kamerahalterung_stkl.pdf|}} 
  
projects/bif-monitor/application.txt · Last modified: 2011/08/24 18:06 by candre