instruments:overview:ccc [2015/12/16 11:28]
phebyn [Recent Developments]
instruments:overview:ccc [2022/02/07 07:46]
dhaider [Further Information]
Line 1: Line 1:
 =====Cryogenic Current Comparator (CCC)===== =====Cryogenic Current Comparator (CCC)=====
-The CCC is a cryogenic DC beam current transformer. It measures the intensity of lowest beam currents, circulating in storage rings, or extracted through high energy beam transport lines. The present best values, obtained with a thin-film DC SQUID at 4 K, are: +The CCC is a cryogenic DC beam current transformer. It measures the intensity of lowest beam currents, circulating in storage rings, or extracted through high energy beam transport lines. The present best values, obtained with a thin-film DC SQUID at 4.2 K, are: 
  
   * Current resolution < 6-120 pA/sqrt(Hz) (within a bandwidth of DC-10 kHz)   * Current resolution < 6-120 pA/sqrt(Hz) (within a bandwidth of DC-10 kHz)
Line 25: Line 25:
 \\ \\
 ==== Further Information ==== ==== Further Information ====
-[[projects:CCC:drawings|drawings of the existing GSI-CCC prototype (selected)]]\\ 
-\\ 
 [[projects:CCC:papers|Publications highlighting basics and details of CCCs]]\\ [[projects:CCC:papers|Publications highlighting basics and details of CCCs]]\\
 +\\ 
 +[[projects:CCC:documentation|CCC technical documents]]\\ 
 +\\ 
 +Positioning of first Cryocompressor for CCC "T1S1DT1Y": {{ :instruments:overview:kuehlwasser18ccc.pps |Positionierung Cryo-Kompressor}}  !\\ 
 +\\ 
 +CCC elog: https://elog.gsi.de/CCC/CCC/ \\
instruments/overview/ccc.txt · Last modified: 2022/09/01 09:19 by carsten